Baltimore City · 21206
3705 FRANKFORD AVE
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $305,567
- Land use
- Residential (R)
- Year built
- 1929
- Last sale
- Jan 13, 2021
Assessment
| Owner | ESTRADA, DARWIN I |
|---|---|
| Land use | Residential (R) |
| Total assessment | $305,567 (cycle 2026) |
| Last sale | Jan 13, 2021 — $265,000 |
| Year built | 1929 |
| Zoning | R-3 |
| Vacant | — |
Permits
10| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2020 | AA CONV: Full Description Loaded as Comment | — | Aug 28, 2020 |
| COM2020 | Extend Original Permit.(original permit:COM2020-50608:INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 80000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2020-50608) INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 80000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Aug 28, 2020 |
| COM2020 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-82933:INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.) Original Permit Description:(COM2019-82933) INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | — | Aug 21, 2020 |
| COM2020 | Extend Original Permit.(original permit:COM2020-52531:INSTALL (7) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE.) Original Permit Description:(COM2020-52531) INSTALL (7) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE. | — | Aug 21, 2020 |
| COM2020 | AMEND PERMIT: CHANGE PLUMBER AND GAS CONTRACTOR . (ORIGINAL PERMIT:COM2019-81458:INSTALL (7) # PLUMBING FIXTURES, (3) 155000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2019-81458) INSTALL (7) # PLUMBING FIXTURES, (3) 155000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Feb 5, 2020 |
| COM2020 | INSTALL (7) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE. | $6,700 | Jan 27, 2020 |
| COM2020 | INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 80000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP AS PER CODE. | $5,800 | Jan 10, 2020 |
| COM2019 | install (30) # branch circuits/feeders , (1) 200 amps electric service up to 600v (#amps) as per code. | $1,500 | Oct 31, 2019 |
| COM2019 | install (7) # plumbing fixtures, (3) 155000 btu fuel-burning equip as per code. | $2,500 | Oct 24, 2019 |
| COM2019 | description of work to be done:--interior alterations-- perimeter frame entire basement area to create a full bathroom, laundry room, utility room and bed room.--exterior alterations--rebuild rear deck using existing old deck posts main basement • perimeter frame entire basement outside walls approx. 100 linear feet ( non structural standard 2x4 construction 16” oc. insulate all outside walls ( r 19 ) • frame basement laundry room wall approx. 23’ from left to right side at rear of structure ( non structural standard 2x4 construction 16” oc. insulate all outside walls ( r 19 ) • frame 2x4 side basement stairway wall to secure steps in enclosure and to create closet under steps structural standard 2x4 construction 16” oc. insulate all outside walls ( r 19 ) • frame wall area for a basement bathroom approx.. 6’ x 8’ feet ( non structural standard 2x4 construction 16” oc. insulate all outside walls ( r 19 ) • pressure treated base plate throughout secured with 3” ramset nails with washers • frame bedroom wall with 2x8 lumber double top plated and secured under existing basement timber to transfer load newly installed living room central beam and 4x6 supports. a[pprox. 350 sqft. with egress window • window framing and size is to comply with egress code standards 1st floor living room main area • install 2 – 2x12x1.5 beams sandwiched from left to right of main structure to open room and remove existing load walls in center of structure. ( see drawings ) • install 4x6 beams that transfer the load from basement through to second floor • center beam support is to • frame hvac duct at rear of property to enclose. 1st floor powder room • frame with 2x4’s to enclosure and to create a powder room approx.. 5’x6’ non structural interior walls standard 2x4 construction 16” oc. insulate all outside walls ( r 19 ) 2nd floor bathroom • install new .75” plywood to bathroom floor to replace old floor sheathing ( glue and screw with 3” star head screws 2md floor duct chase • frame 2x4 wall to encl as per plans and as per code, separate permit will be pulled for mep. | $1,500 | Oct 11, 2019 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 8, 2026 · 136 m · 5408 PEMBROKE AVE
- violation: HCD-Sanitation PropertyJul 2, 2026 · 92 m · 5401 PEMBROKE AVE
- violation: HCD-Sanitation PropertyJun 7, 2026 · 61 m · 3712 GIBBONS AVE
- violation: PM 306.1Jun 1, 2026 · 141 m · 3726 FRANKFORD AVE
- violation: HCD-Sanitation PropertyMay 19, 2026 · 140 m · 3726 FRANKFORD AVE
- permit: BRCMApr 27, 2026 · 92 m · 5402 HILLBURN AVE
- permit: BRCMApr 21, 2026 · 116 m · 3721 GIBBONS AVE
- violation: HCD-Sanitation PropertyApr 8, 2026 · 121 m
- permit: BRCMMar 12, 2026 · 96 m · 3612 FRANKFORD AVE
- permit: BRCMJan 20, 2026 · 139 m · 5403 CRESTON AVE
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;