Assessment
| Owner | DAVIS, DRACY |
|---|---|
| Land use | Residential (R) |
| Total assessment | $230,233 (cycle 2026) |
| Last sale | Oct 21, 2024 — $297,500 |
| Year built | 1955 |
| Zoning | R-4 |
| Vacant | — |
Permits
7| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2024 | CONSTRUCT A NEW DECK AT 1ST FLOOR REAR AS PER PLANS AS PER ODE. | $11,000 | Oct 18, 2024 |
| USE2024 | USE AS A SINGLE-FAMILY DWELLING. | — | Jul 18, 2024 |
| COM2023 | WORK DESCRIPTION 1ST FLOOR LIVING ROOM STRUCTURAL WALL ALTERATION • TEMPORARILY SUPPORT FLOOR ABOVE WITH BRACING TO PREP FOR DOUBLE BEAM INSTALL • INSTALL 2 LAMINATED 10” BEAMS 10’ FEET IN LENGTH TO OPEN UP THROUGHWAY FROM LIVING ROOM TO DINING ROOM AREA • LOAD POINT ARE TO SIT DIRECTLY ON TOP OF STEEL “I” BEAM IN THE BASEMENT • INSTALLED 2 BEAMS ARE TO BE 10’ LONG 10’’ 1.5 INCHES THICK WITH PLYWOOD IN BETWEEN BASEMENT LIVING AREA WITH LAUNDRY, UTILITY ROOM AND POWDER ROOM. • PERIMETER FRAME ALL BASEMENT WALLS WITH STANDARD 2X4 LUMBER CONSTRUCTION 16” ON CENTER. • BOTTOM PLATE TO BE PRESSURE TREATED LUMBER FOR GROUND CONTACT. • BOTTOM PLATE IS TO BE SECURED TO CONCRETE FLOOR WITH CONCRETE NAILS. • ALL NEW WALLS ARE NON-STRUCTURAL. • FRAMING IS TO INCLUDE A BASEMENT LAUNDRY ROOM APPROX. 7’X5’ IN DIMENSIONS TO ACCOMMODATE A SIDE-BY-SIDE WASHER DRYER SEE DRAWING. • FRAMING IS TO INCLUDE A UTILITY ROOM APPROX. 5’X7’ TO ENCASE BOTH THE HVAC FURNACE AND WATER HEATER ROOM IS TO HAVE LOUVERED VENTS FOR AIR FLOW. • BASEMENT FRAMING INCLUDES A POWDER ROOM TO THE RIGHT OF THE REAR BASEMENT EGRESS DOOR. THE BATHROOM IS TO BE APPROX. 5’X6’ IN SIZE. WITH A 30” RIGHT SWING DOOR • ALL OUTSIDE EXTERIOR WALLS ARE TO BE INSULATED. 2ND FLOOR MASTER SUITE WITH ADDITIONAL FULL BATHROOM • 2ND FLOOR CLOSET AT THE TOP OF THE STEPS IS TO BE FRAMED CLOSED USING STANDARD 2X4 CONSTRUCTION 16” ON CENTER. • NEW WALL IS TO BE SECURED TO BOTH FLOOR AND CEILING WITH NAILS. • SMALL SIDE WALL OF EXISTING MASTER BATH IS TO BE REMOVED TO OPEN ARE FOR NEW MASTER BATHROOM SHOWER LOCATION (SEE DRAWING) • 32’X48” SHOWER TO BE FRAMED WHERE OLD HALLWAY CLOSET USED TO EXIST. • SMALL DIVIDER WALL TO BE BUILT USING STANDARD 2X4 CONSTRUCTION 16” ON CENTER FOR SIDE SHOWER WALL AREA TO SEPARATE FROM TOILET AND VANITY • ALL FRAMING ON 2ND FLOOR IS TO BE NON STRUCTURAL AND NO STRUCTURAL WALLS ARE TO BE REMOVED 2ND FLOOR MASTER SUITE WITH ADDITIONAL FULL BATH. SEPARATE PERMIT IS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING. EXTERIOR WINDOWS AND DOORS REPLACEMENT WILL BE SAME SIZES AND LOCATIONS. ALL WORK PER CODE. | $5,500 | Mar 18, 2024 |
| COM2024 | INSTALL (1) # BACKFLOW PREVENTION DEVICE (<2'' DIAMETER), (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (4) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 16000 BTU FUEL-BURNING EQUIP AS PER CODE. | $2,000 | Feb 12, 2024 |
| COM2024 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 70000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 1000 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ) AS PER CODE. | $6,800 | Jan 31, 2024 |
| COM2024 | INSTALL (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (18) # BRANCH CIRCUITS/FEEDERS , (80) # FIXTURES/DEVICES AS PER CODE. | $3,000 | Jan 30, 2024 |
| COM2024 | REMOVAL OF OUTSIDE RAILING AND REPLACED WITH WOODEN RAILING - REMOVAL OF EXTERIOR PATIO AWNING - DEMO OF INTERIOR KITCHEN WALL (NON STRUCTURAL) TO OPEN KITCHEN ENTRANCE. AS PER CODE. | $100 | Jan 8, 2024 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: PM 305.2.2Jun 23, 2026 · 117 m · 1521 BURNWOOD RD
- violation: PM 306.2Jun 23, 2026 · 117 m · 1521 BURNWOOD RD
- violation: HCD-Sanitation PropertyJun 20, 2026 · 118 m · 1521 BURNWOOD RD
- violation: SW-Dirty AlleyMay 26, 2026 · 112 m · 1524 WINFORD RD
- violation: PM 305.1May 19, 2026 · 96 m · 1500 BURNWOOD RD
- violation: HCD-Sanitation PropertyMay 13, 2026 · 96 m · 1500 BURNWOOD RD
- violation: HCD-Sanitation PropertyMay 12, 2026 · 96 m · 1500 BURNWOOD RD
- violation: HCD-Sanitation PropertyMay 12, 2026 · 96 m · 1500 BURNWOOD RD
- violation: PM 305.2.2May 6, 2026 · 96 m · 1500 BURNWOOD RD
- permit: BUSEMay 5, 2026 · 62 m · 1510 WINFORD RD