Permits

24
TypeDescriptionCostIssued
COM2024REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-88519:INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.) Original Permit Description:(COM2022-88519) INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.Oct 25, 2024
COM2024 REINSTATE ORIGINAL PERMIT. (ORIGINAL PERMIT:COM2022-88357:INSTALL (1) 48 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS), (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS) AS PER CODE.) Original Permit Description:(COM2022-88357) INSTALL (1) 48 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS), (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS) AS PER CODE.Oct 11, 2024
COM2024 REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-88519:INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.) Original Permit Description:(COM2022-88519) INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.Sep 10, 2024
COM2024REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-88519:INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.) Original Permit Description:(COM2022-88519) INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.Jun 5, 2024
COM2024WE ARE DIGGING DOWN BELOW FROST LINE, POURING IN CONCRETE PAD AND THEN BLOCKS SO THAT THE STAIR LANDING WILL NOT MOVE WITH FROST AND SUPPORT THE WEIGHT OF THE STAIRS. REDOING LANDING AREA OF FRONT PORCH TO BETTER SUPPORT DECK STEPS TREAD. AS PER CODE.$2,000Apr 17, 2024
COM2024 Extend Original Permit.(original permit:COM2023-80517:OBJECTIVE- TO REPLACE EXISTING 3/12 PITCH SEVERELY DAMAGED GARAGE ROOF, WITH NEW 6/12 PITCH ROOF FRAMED TO CODE. REMODEL EXTERIOR OF GARAGE. TO BE PREFORMED— - DEMO EXISTING ROOF, INCLUDING SHINGLES, SHEATHING, RAFTERS AND GABLE ENDS. - DEMO FRONT WALL AS NEEDED AND BEAM OVER THE OVERHEAD DOOR, TO ADD NEW BEAM TO BRING UP TO CODE. - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN SILL PLATE - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN TOP PLATE. - DEMO AND REMOVE EXISTING CEDAR SHAKE SIDING, TO BE REPLACED WITH WHITE BY AL SIDING TO MATCH HOUSE. - NEW 12” LVL BEAM ON FRONT WALL TO SPAN CORNER TO CORNER FOR 16’ GARAGE DOOR, WITH 2X6 FRAMING 16” ON CENTER. - NEW REAR ENTRY DOOR, TO REPLACE EXISTING IN CURRENT LOCATION, ADD 2”X10” HEADER OVER DOOR. - ADD NEW 6’X3’ AWNING WINDOW ON REAR SIDE OF GARAGE WITH 2X10” HEADER. - NEW 6/12 PITCH “A” FRAME ROOF OVER GARAGE, WITH 2”X8” RAFTERS 16” ON CENTER. WITH NEW 2”X10” RIDGE BEAM. * PROPOSED 6/12 ROOF PITCH TO KEEP ICE AND SNOW BUILD UP FROM HAPPENING AS BADLY, ALSO TO GIVE SMALL STORAGE SPACE IN CEILING OF GARAGE. AND TO TRY AND MATCH HOUSE ROOF PITCH A LITTLE CLOSER. HOUSE PITCH IS A 12/12. - NEW 2”X6” COLLAR TIES ON EVERY RAFTER SET. - NEW 2”X6” CEILING TIES ON EVERY RAFTER SET. - NEW GABLE ENDS TO BE FRAMED WITH 2”X6” LUMBER 16” ON CENTER STACKED OVER WALL LAYOUT. - SISTER NEW 2”X6” LUMBER TO EXISTING 2”X4” “ACTUAL” EXISTING FRAMING 16” ON CENTER TO PAD WALLS IN AND TO PLANE AND SQUARE UP EXISTING WALLS ON EXISTING FOUNDATION. - HURRICANE TIES ON EVERY RAFTER AT WALL. - NEW WHITE VINYL SIDING TO MATCH EXISTING HOUSE SIDING. - NEW METAL OR ASPHALT ROOF SHINGLES. AS PER PLANS AND AS PER CODE. ) Original Permit Description:(COM2023-80517) OBJECTIVE- TO REPLACE EXISTING 3/12 PITCH SEVERELY DAMAGED GARAGE ROOF, WITH NEW 6/12 PITCH ROOF FRAMED TO CODE. REMODEL EXTERIOR OF GARAGE. TO BE PREFORMED— - DEMO EXISTING ROOF, INCLUDING SHINGLES, SHEATHING, RAFTERS AND GABLE ENDS. - DEMO FRONT WALL AS NEEDED AND BEAM OVER THE OVERHEAD DOOR, TO ADD NEW BEAM TO BRING UP TO CODE. - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN SILL PLATE - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN TOP PLATE. - DEMO AND REMOVE EXISTING CEDAR SHAKE SIDING, TO BE REPLACED WITH WHITE BY AL SIDING TO MATCH HOUSE. - NEW 12” LVL BEAM ON FRONT WALL TO SPAN CORNER TO CORNER FOR 16’ GARAGE DOOR, WITH 2X6 FRAMING 16” ON CENTER. - NEW REAR ENTRY DOOR, TO REPLACE EXISTING IN CURRENT LOCATION, ADD 2”X10” HEADER OVER DOOR. - ADD NEW 6’X3’ AWNING WINDOW ON REAR SIDE OF GARAGE WITH 2X10” HEADER. - NEW 6/12 PITCH “A” FRAME ROOF OVER GARAGE, WITH 2”X8” RAFTERS 16” ON CENTER. WITH NEW 2”X10” RIDGE BEAM. * PROPOSED 6/12 ROOF PITCH TO KEEP ICE AND SNOW BUILD UP FROM HAPPENING AS BADLY, ALSO TO GIVE SMALL STORAGE SPACE IN CEILING OF GARAGE. AND TO TRY AND MATCH HOUSE ROOF PITCH A LITTLE CLOSER. HOUSE PITCH IS A 12/12. - NEW 2”X6” COLLAR TIES ON EVERY RAFTER SET. - NEW 2”X6” CEILING TIES ON EVERY RAFTER SET. - NEW GABLE ENDS TO BE FRAMED WITH 2”X6” LUMBER 16” ON CENTER STACKED OVER WALL LAYOUT. - SISTER NEW 2”X6” LUMBER TO EXISTING 2”X4” “ACTUAL” EXISTING FRAMING 16” ON CENTER TO PAD WALLS IN AND TO PLANE AND SQUARE UP EXISTING WALLS ON EXISTING FOUNDATION. - HURRICANE TIES ON EVERY RAFTER AT WALL. - NEW WHITE VINYL SIDING TO MATCH EXISTING HOUSE SIDING. - NEW METAL OR ASPHALT ROOF SHINGLES. AS PER PLANS AND AS PER CODE. Apr 12, 2024
COM2024REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-73430:INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, AS PER PLANS, AS PER CODE ) Original Permit Description:(COM2023-73430) INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, AS PER PLANS, AS PER CODE Apr 12, 2024
COM2024REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-62161:INSTALL (14) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.) Original Permit Description:(COM2023-62161) INSTALL (14) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.Feb 23, 2024
COM2023OBJECTIVE- TO REPLACE EXISTING 3/12 PITCH SEVERELY DAMAGED GARAGE ROOF, WITH NEW 6/12 PITCH ROOF FRAMED TO CODE. REMODEL EXTERIOR OF GARAGE. TO BE PREFORMED— - DEMO EXISTING ROOF, INCLUDING SHINGLES, SHEATHING, RAFTERS AND GABLE ENDS. - DEMO FRONT WALL AS NEEDED AND BEAM OVER THE OVERHEAD DOOR, TO ADD NEW BEAM TO BRING UP TO CODE. - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN SILL PLATE - DEMO AND REPLACE APPROXIMATELY 8’ OF ROTTEN TOP PLATE. - DEMO AND REMOVE EXISTING CEDAR SHAKE SIDING, TO BE REPLACED WITH WHITE BY AL SIDING TO MATCH HOUSE. - NEW 12” LVL BEAM ON FRONT WALL TO SPAN CORNER TO CORNER FOR 16’ GARAGE DOOR, WITH 2X6 FRAMING 16” ON CENTER. - NEW REAR ENTRY DOOR, TO REPLACE EXISTING IN CURRENT LOCATION, ADD 2”X10” HEADER OVER DOOR. - ADD NEW 6’X3’ AWNING WINDOW ON REAR SIDE OF GARAGE WITH 2X10” HEADER. - NEW 6/12 PITCH “A” FRAME ROOF OVER GARAGE, WITH 2”X8” RAFTERS 16” ON CENTER. WITH NEW 2”X10” RIDGE BEAM. * PROPOSED 6/12 ROOF PITCH TO KEEP ICE AND SNOW BUILD UP FROM HAPPENING AS BADLY, ALSO TO GIVE SMALL STORAGE SPACE IN CEILING OF GARAGE. AND TO TRY AND MATCH HOUSE ROOF PITCH A LITTLE CLOSER. HOUSE PITCH IS A 12/12. - NEW 2”X6” COLLAR TIES ON EVERY RAFTER SET. - NEW 2”X6” CEILING TIES ON EVERY RAFTER SET. - NEW GABLE ENDS TO BE FRAMED WITH 2”X6” LUMBER 16” ON CENTER STACKED OVER WALL LAYOUT. - SISTER NEW 2”X6” LUMBER TO EXISTING 2”X4” “ACTUAL” EXISTING FRAMING 16” ON CENTER TO PAD WALLS IN AND TO PLANE AND SQUARE UP EXISTING WALLS ON EXISTING FOUNDATION. - HURRICANE TIES ON EVERY RAFTER AT WALL. - NEW WHITE VINYL SIDING TO MATCH EXISTING HOUSE SIDING. - NEW METAL OR ASPHALT ROOF SHINGLES. AS PER PLANS AND AS PER CODE. $5,000Oct 13, 2023
COM2023FOUNDATION WATERPROOFING - EXTERIOR EXCAVATION BELOW EXISTING CONCRETE BASEMENT SLAB. PARGE AND TAR EXTERIOR PORTIONS OF OUTSIDE FOUNDATION (BELOW GRADE) (TWO SIDES OF THE HOUSE. INSTALL RAIN LEADERS AND RUN TO DAYLIGHT. EXTERIOR BASEMENT DOOR AREAWAY -DIG FOR FOOTERS BELOW FROST, LAY 8 INCH BLOCK UP TO GRADE, INSTALL EXTERIOR DRAIN AND RUN TO DAYLIGHT UNDERGROUND ELECTRICAL - DIG OUT A 3 FOOT DEEP TRENCH FROM REAR OF PROPERTY TO BOTH GARAGE AREA AND BACK OF THE HOUSE. INSTALL 4 INCH CONDUIT AND BACKFILL NO UNDERPINING ALL WORK PER CODE ALL WORK INSIDE PROPERTY LINE.ALL WORK PER CODE. YOU MUST CONTACT THE ELECTRICAL OFFICIAL AUTHORITY TO GET THE ELECTRICAL LINES LOCATIONS TO BE PROTECTED DURING THE EXCAVATION. $5,000Sep 8, 2023
COM2023INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, AS PER PLANS, AS PER CODE $30,000Jul 25, 2023
COM2023NEW INTERIOR WORK: INSTALL NEW COLLAR TIES. NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. $10,000Jul 21, 2023
COM2023REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-63044:NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. ) Original Permit Description:(COM2022-63044) NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. Jun 13, 2023
COM2023INSTALL (14) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.$600Apr 13, 2023
COM2023REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-63044:NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. ) Original Permit Description:(COM2022-63044) NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. Mar 21, 2023
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-63044:NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. ) Original Permit Description:(COM2022-63044) NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. Jan 9, 2023
COM2022INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 76000 BTU FUEL-BURNING EQUIP, (5) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (4) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) 16000 BTU FUEL-BURNING EQUIP, (2) 120000 BTU FUEL-BURNING EQUIP, (1) 22000 BTU FUEL-BURNING EQUIP, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES AS PER CODE.$8,000Nov 23, 2022
COM2022SCOPE OF WORK: ELECTRICAL ALTERATIONS TO INCLUDE: ELECTRICAL REWIRE: INSTALLATION OF 100 FIXTURES/DEVICES, 14 CIRCUITS AND 20 LOW VOLTAGE DEVICES, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$10,000Nov 21, 2022
COM2022INSTALL (1) 48 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS), (1) # DISTRIBUTION SYSTEM, RECONSTRUCTION ( # DIFFUSERS) AS PER CODE.$60,000Nov 18, 2022
COM2022NEW INTERIOR WORK: INSTALL NEW COLLAR TIES NEW EXTERIOR WORK: DEMO / REBUILD EXISTING FRONT COVERED PORCH (28'-2'' X 10'-6'') X (8'-10'' X 26'-6'') W/ STAIRCASE TO EX. GRADE, SAME SIZE & LOCATION. AS PER PLANS, AS PER CODE. $10,000Apr 27, 2022
COM2022 Extend Original Permit.(original permit:COM2021-73750:INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, REPLACE FRONT PORCH RAILINGS TO CODE (MINIMUM HEIGHT: 36''/MAXIMUM SPACING: 4''). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) ) Original Permit Description:(COM2021-73750) INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, REPLACE FRONT PORCH RAILINGS TO CODE (MINIMUM HEIGHT: 36''/MAXIMUM SPACING: 4''). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) Apr 1, 2022
COM2021INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS. NEW FLOOR JOISTS/BEAMS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (5). NEW EXTERIOR WORK: EXTERIOR DOORS (2), WINDOWS (8). INSTALL NEW SIDING ON EXTERIOR, REPLACE FRONT PORCH RAILINGS TO CODE (MINIMUM HEIGHT: 36''/MAXIMUM SPACING: 4''). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) $30,000Aug 9, 2021
COM2021SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: WINDOW REPLACEMENT, REPLACE EXISTING WINDOWS WITH NEW ENERGY STAR RATED WINDOWS. ALL WINDOWS TO BE SIZED TO FIT INTO EXISTING WINDOW OPENING. NO STRUCTURAL CHANGES WILL BE MADE, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$5,500Feb 5, 2021
COM2020SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: DECK AND STAIRCASE CONSTRUCTION, REPLACING EXISTING REAR DECK IN SAME LOCATION, 8' X 8' WITH STEPS (ALL LUMBER TO BE PT., REPAIR EXISTING PORCH AT RH SIDE OF HOUSE. WILL REPLACE WATER DAMAGED BEAM AND FLOOR), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS (*NOTES: 1. ALL WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES, 2. LEDGER BOARD WILL BE THRU BOLTED AND CONNECTED TO HOME, 3. STAIRCASE PARAMETERS: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN, 4. FOOTERS WILL BE AT LEAST 30'' DEEP/RAILINGS MINIMUM HEIGHT: 36'' AND MAXIMUM SPACING: 4'') $8,200Jan 1, 2021

Violations

1
KindCategoryStatusDate
service_requestSW-Dirty AlleyClosedMay 4, 2026