Baltimore City · 21210

106 WOODLAWN RD

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$1,126,200
Land use
Commercial (C)
Year built
1900
Last sale
Feb 15, 2023

Assessment

OwnerFEIN, ARIELLE WENDY
Land useCommercial (C)
Total assessment$1,126,200 (cycle 2026)
Last saleFeb 15, 2023 — $1,575,000
Year built1900
ZoningR-1-E
Vacant

Permits

8
TypeDescriptionCostIssued
BRCMEmergency sewer lateral replacement.$10,175Aug 21, 2025
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-88045:INTERIOR RENOVATION TO AN EXISTING 3-STORY SINGLE FAMILY DWELLING AND A PROPOSED 140 SF REAR ADDITION. DEMOLITION WORK INCLUDES THE REMOVAL OF NON LOAD BEARING INTERIOR PARTITIONS, FIXTURES, FITTINGS, AND FINISHES TO ACCOMMODATE A REVISED INTERIOR LAYOUT. THREE LOAD BEARING INTERIOR WALLS WILL BE DEMOLISHED AND REPLACED WITH W12X30 STEEL BEAMS TO PROVIDE A MORE OPEN FLOOR PLAN ON THE FIRST FLOOR. THE EXISTING COVERED LANDING LOCATED AT THE REAR DOOR WILL BE REMOVED TO ACCOMMODATE THE PROPOSED ADDITION. THE PROPOSED 140 SQUARE FOOT REAR ADDITION WILL CONSIST OF A MUD ROOM AND HALF-BATH. THE PROPOSED LOAD-BEARING EXTERIOR WALLS WILL BE CONSTRUCTED WITH 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER, BEARING ON CAST-IN-PLACE CONCRETE FOUNDATION WALLS. THE FLOOR FRAMING OF THE REAR ADDITION WILL BE 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER AND BEAR ON THE PROPOSED FOUNDATION WALLS. THE ROOF FRAMING WILL BE 2X12 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER BEARING ON THE PROPOSED EXTERIOR WALLS.THE PROPOSED EXTERIOR LANDING WILL BE CONSTRUCTED USING 2X12 NOMINAL PRESSURE TREATED WOOD DECK JOISTS BEARING ON 2X12 NOMINAL PRESSURE TREATED WOOD BEAM JOISTS SUPPORTED BY 6X6 NOMINAL PRESSURE TREATED WOOD POSTS AND CAST-IN-PLACE CONCRETE FOOTINGS. NO CHANGE TO EXISTING BUILDING HEIGHT, NO CHANGE OF USE, AND ALL WORK WILL BE DONE ACCORDING TO SUBMITTED DRAWINGS. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY CODES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)) Original Permit Description:(COM2021-88045) INTERIOR RENOVATION TO AN EXISTING 3-STORY SINGLE FAMILY DWELLING AND A PROPOSED 140 SF REAR ADDITION. DEMOLITION WORK INCLUDES THE REMOVAL OF NON LOAD BEARING INTERIOR PARTITIONS, FIXTURES, FITTINGS, AND FINISHES TO ACCOMMODATE A REVISED INTERIOR LAYOUT. THREE LOAD BEARING INTERIOR WALLS WILL BE DEMOLISHED AND REPLACED WITH W12X30 STEEL BEAMS TO PROVIDE A MORE OPEN FLOOR PLAN ON THE FIRST FLOOR. THE EXISTING COVERED LANDING LOCATED AT THE REAR DOOR WILL BE REMOVED TO ACCOMMODATE THE PROPOSED ADDITION. THE PROPOSED 140 SQUARE FOOT REAR ADDITION WILL CONSIST OF A MUD ROOM AND HALF-BATH. THE PROPOSED LOAD-BEARING EXTERIOR WALLS WILL BE CONSTRUCTED WITH 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER, BEARING ON CAST-IN-PLACE CONCRETE FOUNDATION WALLS. THE FLOOR FRAMING OF THE REAR ADDITION WILL BE 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER AND BEAR ON THE PROPOSED FOUNDATION WALLS. THE ROOF FRAMING WILL BE 2X12 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER BEARING ON THE PROPOSED EXTERIOR WALLS.THE PROPOSED EXTERIOR LANDING WILL BE CONSTRUCTED USING 2X12 NOMINAL PRESSURE TREATED WOOD DECK JOISTS BEARING ON 2X12 NOMINAL PRESSURE TREATED WOOD BEAM JOISTS SUPPORTED BY 6X6 NOMINAL PRESSURE TREATED WOOD POSTS AND CAST-IN-PLACE CONCRETE FOOTINGS. NO CHANGE TO EXISTING BUILDING HEIGHT, NO CHANGE OF USE, AND ALL WORK WILL BE DONE ACCORDING TO SUBMITTED DRAWINGS. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY CODES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)Sep 26, 2022
COM2022 Extend Original Permit.(original permit:COM2022-55863:INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.) Original Permit Description:(COM2022-55863) INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.Sep 13, 2022
COM2022INSTALL (1) 70000 BTU FUEL-BURNING EQUIP AS PER CODE.$2,500May 5, 2022
COM2022INSTALL (6) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (7) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (3) # PLUMBING FIXTURES, (3) # PLUMBING FIXTURES, (1) # GAS TEST, (1) 190000 BTU FUEL-BURNING EQUIP, (1) 12000 BTU FUEL-BURNING EQUIP, (1) 15000 BTU FUEL-BURNING EQUIP, (1) 75000 BTU FUEL-BURNING EQUIP AS PER CODE.$6,500May 4, 2022
COM2022SCOPE OF WORK: ELECTRICAL ALTERATIONS TO INCLUDE: ADD 40 CIRCUITS, SUB PANEL, REPLACE MAIN PANEL, ADD AS MUCH NEW WIRING AS POSSIBLE, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$5,000Apr 20, 2022
COM2022INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$10,000Feb 17, 2022
COM2021INTERIOR RENOVATION TO AN EXISTING 3-STORY SINGLE FAMILY DWELLING AND A PROPOSED 140 SF REAR ADDITION. DEMOLITION WORK INCLUDES THE REMOVAL OF NON LOAD BEARING INTERIOR PARTITIONS, FIXTURES, FITTINGS, AND FINISHES TO ACCOMMODATE A REVISED INTERIOR LAYOUT. THREE LOAD BEARING INTERIOR WALLS WILL BE DEMOLISHED AND REPLACED WITH W12X30 STEEL BEAMS TO PROVIDE A MORE OPEN FLOOR PLAN ON THE FIRST FLOOR. THE EXISTING COVERED LANDING LOCATED AT THE REAR DOOR WILL BE REMOVED TO ACCOMMODATE THE PROPOSED ADDITION. THE PROPOSED 140 SQUARE FOOT REAR ADDITION WILL CONSIST OF A MUD ROOM AND HALF-BATH. THE PROPOSED LOAD-BEARING EXTERIOR WALLS WILL BE CONSTRUCTED WITH 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER, BEARING ON CAST-IN-PLACE CONCRETE FOUNDATION WALLS. THE FLOOR FRAMING OF THE REAR ADDITION WILL BE 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER AND BEAR ON THE PROPOSED FOUNDATION WALLS. THE ROOF FRAMING WILL BE 2X12 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER BEARING ON THE PROPOSED EXTERIOR WALLS.THE PROPOSED EXTERIOR LANDING WILL BE CONSTRUCTED USING 2X12 NOMINAL PRESSURE TREATED WOOD DECK JOISTS BEARING ON 2X12 NOMINAL PRESSURE TREATED WOOD BEAM JOISTS SUPPORTED BY 6X6 NOMINAL PRESSURE TREATED WOOD POSTS AND CAST-IN-PLACE CONCRETE FOOTINGS. NO CHANGE TO EXISTING BUILDING HEIGHT, NO CHANGE OF USE, AND ALL WORK WILL BE DONE ACCORDING TO SUBMITTED DRAWINGS. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY CODES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)$80,000Dec 15, 2021

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;