Permits

6
TypeDescriptionCostIssued
COM2023INSTALL (4) # BRANCH CIRCUITS/FEEDERS , (25) # FIXTURES/DEVICES AS PER CODE.$4,000Jun 30, 2023
COM2023INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$7,000May 8, 2023
COM2023CONFIGURATION AMENDMENT TO PERMIT COM2022-88978 NEW ONE (1) STORY ADDITION TO EXISTING SINGLE-FAMILY RESIDENCE. WORK INCLUDES; EXCAVATE, FORM & POUR 4”, 3,500 PSI CONCRETE SLAB ON GRADE WITH 6X6 WELDED WIRE FABRIC OVER 4” CR6 GRAVEL AND 6 MIL POLY VAPOR BARRIER. SLAB HAS INTEGRATED TURN-DOWN FOOTERS; 14” WIDE BY 28” DEEP WITH #6 REBAR. INSTALL 2” RIGID INSULATION ENTIRE PERIMETER OF SLAB. EXTERIOR WALLS ARE TYVEX BUILDING WRAP OVER ½” EXTERIOR GRADE PLYWOOD SHEATHING APPLIED TO 2” X 6” WOOD STUDS @ 16” O.C. WITH R-19 BATT INSULATION AND ½” GYPSUM BOARD INTERIOR FINISH. EXTERIOR FINISH TO BE VINYL SIDING. INSTALL ONE (1) 72”X80” INSULATED VINYL SLIDING DOOR WITH TWO (2) FIXED LITE TRANSOM WINDOWS. ROOF CONSTRUCTION IS ARCHITECTURAL SHINGLES WITH CERTAINTEED INTEGRITY SYSTEM SUBSTRATE OVER ½” PLYWOOD SHEATHING ON NEW 2” X 10” WOOD RAFTERS @ 16” O.C.; CENTER COMPOSITE BEAM IS TRIPLE (3) 1-3/4” X 11’-7/8” LVL BEAMS SUPPORTED AT BOTH ENDS BY 6”X6” WOOD POST. ROOF INSULATION IS R-30 BATT INSULATION. INSTALL ONE (1) 14 ½” X 36” FIXED SKYLIGHT. INTERIOR VAULTED CEILING IS ½” GYPSUM BOARD. VENTED SOFFIT AND RIDGE VENT TO BE INCLUDED. 5” ALUMINUM K-STYLE GUTTERS (2 SIDES) WITH 3” X 4” DOWNPOUTS TO ON-GRADE SPLASH BLOCKS. EXTENDED CLOSET FLOOR TO BE FRAMED ON TOP OF NEW SLAB TO MATCH EXISTING FIRST FLOOR ELEVATION WITH 2”X12” WOOD JOISTS @ 16” O.C. WITH ¾” PLYWOOD GLUED AND SCREWED. INSTALL NEW INTERIOR WOOD STEPS FROM MAIN LEVEL TO ADDITION FLOOR WITH NEW CENTER HANDRAIL. INSTALL ONE (1) PRE-HUNG HOLLOW CORE INTERIOR DOOR $30,000Apr 9, 2023
COM2022NEW ONE (1) ROOM ADDITION TO EXISTING SINGLE-FAMILY RESIDENCE WITH OPEN MEZZANINE LOFT. NEW CLOSET EXTENDED FROM EXISITNG MASTER BEDROOM. WORK INCLUDES; EXCAVATE, FORM & POUR CONCRETE FOOTING 1’-8” WIDE X 12” DEEP AT 2’-8” BELOW GRADE. INSTALL 8” CONCRETE FILLED CMU FOUNDATION WALLS, TYPICAL THREE (3) SIDES MATCHING ELEVATION OF EXISTING FIRST FLOOR. CREATE CONDITIONED AND INSULATED CRAWLSPACE. INSTALL PERIMETER DRAIN TO NEW SUMP PUMP AND PIT. BACKFILL SOIL TO MATCH EXISTING GRADE. EXTERIOR WALLS ARE TYVEX BUILDING WRAP OVER ½” EXTERIOR GRADE PLYWOOD SHEATHING APPLIED TO 2” X 6” WOOD STUDS @ 16” O.C. WITH R-19 BATT INSULATION AND ½” GYPSUM BOARD INTERIOR FINISH. EXTERIOR FINISH TO BE VINYL SIDING AT TWO (2) STORY ADDITION AND THINSET STONE AT CLOSET EXTENSION. MAIN FLOOR AND LOFT FLOOR SYSTEMS TO BE 11-7/8” OPEN WEB WOOD FLOOR TRUSS WITH ¾” PLYWOOD SUBFLOOR GLUED AND SCREWED TO JOISTS. INSTALL R-30 INSULATION AT 2’-0” PERIMETER OF ADDITION 1ST FLOOR. WOOD STAIRS WITH CLOSED RISERS TO LOFT FROM MAIN LEVEL WITH HANDRAILS AT 36” A.F.F. LOFT FLOOR TO MATCH 1ST FLOOR. ROOF CONSTRUCTION IS ARCHITECTURAL SHINGLES WITH CERTAINTEED INTEGRITY SYSTEM SUBSTRATE OVER ½” PLYWOOD SHEATHING ON NEW WOOD TRUSS @ 16” O.C.. ROOF INSULATION IS R-38 BATT INSULATION. INTERIOR CEILING IS ½” GYPSUM BOARD. VENTED SOFFIT AND RIDGE VENT TO BE INCLUDED. 5” ALUMINUM K-STYLE GUTTERS (2 SIDES) WITH 3” X 4” DOWNPOUTS TO ON-GRADE SPLASH BLOCKS. NEW COMPOSITE DECK WITH 12” DIA. POST FOOTERS TO 2’-8” BELOW GRADE. MAIN SUPPORT BEAMS DBL P.T. 2” X 12”; JOISTS ARE P.T. 2” X 12” WOOD JOISTS @ 12” O.C. TWO (2) SETS OF COMPOSITE STEPS OVER P.T. WOOD STRINGERS TO GRADE. NEW TEMPERED GLASS GUARDRAIL WITH STAINLESS TEEL POSTS TYPICAL ALL SIDES WITH MATCHING HANDRAILS TO GRADE AT STEPS. INSTALL ONE (1) HOLLOW CORE INTERIOR BARN DOOR, ONE (1) LOUVERED INTERIOR WOOD DOOR, TWO (2) 72”X80” INSULATED VINYL SLIDING DOORS WITH TRANSOMS, FOUR (4) INSULATED VINYL WINDOWS WITH TRANSOMS. AS PER PLANS AS PER CODE. ALL SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING.$50,000Mar 21, 2023
COM2019install (1) # branch circuits/feeders , (1) 30000 btu air-con system, condensor, (1) 88000 btu fuel-burning equip(furnace) as per code.$6,957Jun 20, 2019
COM2019install (1) 40000 btu fuel-burning equip as per code.$1,229Mar 22, 2019

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.