Permits

12
TypeDescriptionCostIssued
USE2023USE PREMISES FOR A SINGLE FAMILY DWELLINGJul 31, 2023
COM2023AT FRONT YARD, REPLACE THREE EXISTING CONCRETE STEPS AND EXISTING CONCRETE LEAD WALK TO FRONT PORCH IN EXISTING CONFIGURATION. STEPS ARE 4-FOOT WIDE WITH 12'' TREAD AND 7 3/4'' RISERS (12 SQ. FT.) AND SIDEWALK 4' WIDE X 16' (64 SQ. FT.) INSTALL 4'' OF GRAVEL AND 4'' OF CONCRETE AS PER CODE. (76 SQ. FT. TOTAL)$950May 26, 2023
COM2023SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: AT REAR, INSTALL 3'X8' DECK WITH 3'X3' PLATFORM AND STEPS TO GROUND (33 SQ. FT.) AS PER CODE AND PER DRAWING. ($1,200) AT REAR YARD, REPLACE EXISTING CONCRETE PATIO 18' WIDE X 6' DEEP WITH 4'' GRAVEL AND 4'' OF CONCRETE (108 SQ. FT.). ($1,080), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLAN (*NOTES: 1. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)$2,280May 18, 2023
COM2023 Extend Original Permit.(original permit:COM2022-64066:REMOVE AND REPLACE 5 FRONT WINDOWS AND ONE 1ST FLOOR ENTRY DOOR, SAME SIZE AND LOCATION. WORK TO BE DONE PER CODE.) Original Permit Description:(COM2022-64066) REMOVE AND REPLACE 5 FRONT WINDOWS AND ONE 1ST FLOOR ENTRY DOOR, SAME SIZE AND LOCATION. WORK TO BE DONE PER CODE.Mar 31, 2023
COM2023 Extend Original Permit.(original permit:COM2022-83733:INSTALL INTERIOR FRAMING PER ATTACHED DRAWINGS TO CREATE LIVING ROOM, DINING ROOM, HALF BATH & KITCHEN AT FIRST FLOOR AND 2 BEDROOMS AND A FULL BATH AT 2ND FLOOR. INSTALL R-21 INSULATION AT ALL EXTERIOR WALLS AND R-49 INSULATION AT 2ND FLOOR CEILING. INSTALL 1/2'' DRYWALL TO ALL WALLS AND CEILINGS. INSTALL STEPS FROM BASEMENT TO FIRST FLOOR & FROM 1ST FLOOR TO 2ND FLOOR AS PER CODE. INSTALL INTERIOR TRIM TO INCLUDE BASE BOARD, INTERIOR DOORS AND WINDOW TRIM. INSTALL NEW VINYL FLOOR THROUGHOUT 1ST AND 2ND FLOORS. 1ST FLOOR SQUARE FOOTAGE = 721.60. 2ND FLOOR SQUARE FOOTAGE = 510.40. TOTAL SQUARE FOOTAGE = 1,232 SQ.FT. ALL ELECTRICAL, PLUMBING AND HVAC TO BE PERMITTED & DONE BY OTHERS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ.FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) ) Original Permit Description:(COM2022-83733) INSTALL INTERIOR FRAMING PER ATTACHED DRAWINGS TO CREATE LIVING ROOM, DINING ROOM, HALF BATH & KITCHEN AT FIRST FLOOR AND 2 BEDROOMS AND A FULL BATH AT 2ND FLOOR. INSTALL R-21 INSULATION AT ALL EXTERIOR WALLS AND R-49 INSULATION AT 2ND FLOOR CEILING. INSTALL 1/2'' DRYWALL TO ALL WALLS AND CEILINGS. INSTALL STEPS FROM BASEMENT TO FIRST FLOOR & FROM 1ST FLOOR TO 2ND FLOOR AS PER CODE. INSTALL INTERIOR TRIM TO INCLUDE BASE BOARD, INTERIOR DOORS AND WINDOW TRIM. INSTALL NEW VINYL FLOOR THROUGHOUT 1ST AND 2ND FLOORS. 1ST FLOOR SQUARE FOOTAGE = 721.60. 2ND FLOOR SQUARE FOOTAGE = 510.40. TOTAL SQUARE FOOTAGE = 1,232 SQ.FT. ALL ELECTRICAL, PLUMBING AND HVAC TO BE PERMITTED & DONE BY OTHERS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ.FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) Mar 31, 2023
COM2023INSTALL (7) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE ( 1-2 FAM. RES.), (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 75000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 35000 BTU FUEL-BURNING EQUIP AS PER CODE.$5,800Jan 17, 2023
COM2022INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (55) # FIXTURES/DEVICES, (14) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$6,000Dec 29, 2022
COM2022INSTALL (1) 75000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$10,400Dec 14, 2022
COM2022 Extend Original Permit.(original permit:COM2022-64066:REMOVE AND REPLACE 5 FRONT WINDOWS AND ONE 1ST FLOOR ENTRY DOOR, SAME SIZE AND LOCATION. WORK TO BE DONE PER CODE.) Original Permit Description:(COM2022-64066) REMOVE AND REPLACE 5 FRONT WINDOWS AND ONE 1ST FLOOR ENTRY DOOR, SAME SIZE AND LOCATION. WORK TO BE DONE PER CODE.Oct 19, 2022
COM2022INSTALL INTERIOR FRAMING PER ATTACHED DRAWINGS TO CREATE LIVING ROOM, DINING ROOM, HALF BATH & KITCHEN AT FIRST FLOOR AND 2 BEDROOMS AND A FULL BATH AT 2ND FLOOR. INSTALL R-21 INSULATION AT ALL EXTERIOR WALLS AND R-49 INSULATION AT 2ND FLOOR CEILING. INSTALL 1/2'' DRYWALL TO ALL WALLS AND CEILINGS. INSTALL STEPS FROM BASEMENT TO FIRST FLOOR & FROM 1ST FLOOR TO 2ND FLOOR AS PER CODE. INSTALL INTERIOR TRIM TO INCLUDE BASE BOARD, INTERIOR DOORS AND WINDOW TRIM. INSTALL NEW VINYL FLOOR THROUGHOUT 1ST AND 2ND FLOORS. 1ST FLOOR SQUARE FOOTAGE = 721.60. 2ND FLOOR SQUARE FOOTAGE = 510.40. TOTAL SQUARE FOOTAGE = 1,232 SQ.FT. ALL ELECTRICAL, PLUMBING AND HVAC TO BE PERMITTED & DONE BY OTHERS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ.FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) $50,000Oct 11, 2022
COM2022REMOVE AND REPLACE 5 FRONT WINDOWS AND ONE 1ST FLOOR ENTRY DOOR, SAME SIZE AND LOCATION. WORK TO BE DONE PER CODE.$2,500Apr 21, 2022
COM2020INTERIOR RENOVATION AND 10'-0'' REAR ADDITION TO AN EXISTING SINGLE FAMILY ROW HOME. A NEW 10'-0''X11'-8'' REAR DECK WILL ALSO BE CONSTRUCTED. THE PROPOSED 165 SF REAR ADDITION WILL BE ENCLOSED BY 2X6 NOMINAL EXTERIOR STUD WALLS, WITH AN R21 INSULATION RATING, SUPPORTED BY NEW 10'' THICK CAST-IN-PLACE CONCRETE FOUNDATION WALLS. 2X10 NOMINAL WOOD FLOOR JOISTS WILL BE USED FOR THE FLOOR STRUCTURE. THE NEW INTERIOR LAYOUT WILL BE FRAMED USING 2X4 NOMINAL STUD WALLS AND INCLUDE FOUR BEDROOMS AND THREE BATHROOMS. THE REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 24'' ON CENTER AND SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS WITH CAST-IN-PLACE CONCRETE FOOTINGS. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH CURRENT BALTIMORE CITY BUILDING CODES. THIS PROJECT WAS PREVIOUSLY APPROVED UNDER COM2018-77067ISSUED 5/20/2019. $70,000Jul 13, 2020

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.