Baltimore City · 21229

4619 ROKEBY RD

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$147,900
Land use
Residential (R)
Year built
1942
Last sale
Dec 9, 2022

Assessment

OwnerFAULKNER, MONICA L.
Land useResidential (R)
Total assessment$147,900 (cycle 2026)
Last saleDec 9, 2022 — $46,000
Year built1942
ZoningR-6
Vacant

Permits

8
TypeDescriptionCostIssued
USE2023USE AS A SINGLE-FAMILY DWELLING.Jun 28, 2023
COM2023INSTALL (1) # GAS TEST AS PER CODE.$2,000Jun 14, 2023
COM2023INSTALL (1) 52000 BTU FUEL-BURNING EQUIP AS PER CODE.$150May 26, 2023
COM2023 Extend Original Permit.(original permit:COM2022-85171:RENOVATE EXISTING SINGLE-FAMILY RESIDENCE; INTERIOR WORK ONLY. WORK INCLUDES; REMOVE SELECT NON-BEARING INTERIOR PLASTER WALLS, DOORS, FRAMES & HARDWARE AND CARPET ON 1ST, 2ND AND BASEMENT LEVELS. WOOD FRAME RE-CONFIGURED BASEMENT BATHROOM, PARTIAL 2ND FLOOR BEDROOMS, THREE (3) CLOSETS AND 2ND FLOOR BATHROOM WITH NEW 2” X 4” WOOD STUD WALLS @16” O.C. AT BASEMENT PERIMETER CMU WALLS, INSTALL 1-1/2” METAL FURRING CHANNELS @ 16” O.C. – TWO (2) SIDES ONLY. FRAME MECHANICAL BULKHEAD IN BASEMENT CEILING WITH 2” X 3” WOOD STUDS @ 16”O.C. INSTALL 1 ½” THICK, RIGID FOAM BOARD INSULATION (R-10) AT FURRED CMU WALLS. INSTALL GYPSUM WALL BOARD (GWB) ON NEW STUD WALLS, 1ST AND 2ND FLOOR CEILING INFILLS, BASEMENT CEILING AND MECHANICAL BULKHEADS AS FOLLOWS; STANDARD INTERIOR WALLS, 1ST AND 2ND FLOOR CEILING INFILL - ½” GWB; BATHROOM AND KITCHEN WET WALLS - ½” MOISTURE RESISTANT (M.R.) GWB; TILE / BACKSPLASH LOCATIONS - ½” DUROCK; BASEMENT WALLS, CEILING AND MECHANICAL BULKHEADS - ½” M.R. GWB. ON 1ST AND 2ND FLOOR, INSTALL ½” GYPSUM BOARD DIRECTLY TO EXISTING JOISTS AT ALL CEILING INFILLS. INSTALL ¼” DUROCK OVER EXISTING WOOD SUBFLOOR AT KITCHEN AND 2ND FLOOR BATHROOM FLOOR AS TILE SUBSTRATE. INSTALL THIRTEEN (13) HINGED, HOLLOW CORE INTERIOR DOORS WITH STANDARD HARDWARE AND LOCKSETS. INSTALL SIX (6) HOLLOW CORE DOOR SLABS WITH BI-PASS HARDWARE AT CLOSETS. INSTALL KITCHEN CABINETS AND APPLIANCES. INSTALL CLOSET SHELVING SYSTEMS. INSTALL TOILET ACCESSORIES. INSTALL NEW STAIR HANDRAILS, ALL LEVELS. ALL WORK PER CODE. SEPERATE PERMITS WILL BE REQUESTED FOR MEP WORK. ) Original Permit Description:(COM2022-85171) RENOVATE EXISTING SINGLE-FAMILY RESIDENCE; INTERIOR WORK ONLY. WORK INCLUDES; REMOVE SELECT NON-BEARING INTERIOR PLASTER WALLS, DOORS, FRAMES & HARDWARE AND CARPET ON 1ST, 2ND AND BASEMENT LEVELS. WOOD FRAME RE-CONFIGURED BASEMENT BATHROOM, PARTIAL 2ND FLOOR BEDROOMS, THREE (3) CLOSETS AND 2ND FLOOR BATHROOM WITH NEW 2” X 4” WOOD STUD WALLS @16” O.C. AT BASEMENT PERIMETER CMU WALLS, INSTALL 1-1/2” METAL FURRING CHANNELS @ 16” O.C. – TWO (2) SIDES ONLY. FRAME MECHANICAL BULKHEAD IN BASEMENT CEILING WITH 2” X 3” WOOD STUDS @ 16”O.C. INSTALL 1 ½” THICK, RIGID FOAM BOARD INSULATION (R-10) AT FURRED CMU WALLS. INSTALL GYPSUM WALL BOARD (GWB) ON NEW STUD WALLS, 1ST AND 2ND FLOOR CEILING INFILLS, BASEMENT CEILING AND MECHANICAL BULKHEADS AS FOLLOWS; STANDARD INTERIOR WALLS, 1ST AND 2ND FLOOR CEILING INFILL - ½” GWB; BATHROOM AND KITCHEN WET WALLS - ½” MOISTURE RESISTANT (M.R.) GWB; TILE / BACKSPLASH LOCATIONS - ½” DUROCK; BASEMENT WALLS, CEILING AND MECHANICAL BULKHEADS - ½” M.R. GWB. ON 1ST AND 2ND FLOOR, INSTALL ½” GYPSUM BOARD DIRECTLY TO EXISTING JOISTS AT ALL CEILING INFILLS. INSTALL ¼” DUROCK OVER EXISTING WOOD SUBFLOOR AT KITCHEN AND 2ND FLOOR BATHROOM FLOOR AS TILE SUBSTRATE. INSTALL THIRTEEN (13) HINGED, HOLLOW CORE INTERIOR DOORS WITH STANDARD HARDWARE AND LOCKSETS. INSTALL SIX (6) HOLLOW CORE DOOR SLABS WITH BI-PASS HARDWARE AT CLOSETS. INSTALL KITCHEN CABINETS AND APPLIANCES. INSTALL CLOSET SHELVING SYSTEMS. INSTALL TOILET ACCESSORIES. INSTALL NEW STAIR HANDRAILS, ALL LEVELS. ALL WORK PER CODE. SEPERATE PERMITS WILL BE REQUESTED FOR MEP WORK. May 25, 2023
COM2023INSTALL (1) 150 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (16) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$4,500Jan 26, 2023
COM2023INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (9) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP AS PER CODE.$500Jan 23, 2023
COM2022INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 60000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$1,500Nov 21, 2022
COM2022RENOVATE EXISTING SINGLE-FAMILY RESIDENCE; INTERIOR WORK ONLY. WORK INCLUDES; REMOVE SELECT NON-BEARING INTERIOR PLASTER WALLS, DOORS, FRAMES & HARDWARE AND CARPET ON 1ST, 2ND AND BASEMENT LEVELS. WOOD FRAME RE-CONFIGURED BASEMENT BATHROOM, PARTIAL 2ND FLOOR BEDROOMS, THREE (3) CLOSETS AND 2ND FLOOR BATHROOM WITH NEW 2” X 4” WOOD STUD WALLS @16” O.C. AT BASEMENT PERIMETER CMU WALLS, INSTALL 1-1/2” METAL FURRING CHANNELS @ 16” O.C. – TWO (2) SIDES ONLY. FRAME MECHANICAL BULKHEAD IN BASEMENT CEILING WITH 2” X 3” WOOD STUDS @ 16”O.C. INSTALL 1 ½” THICK, RIGID FOAM BOARD INSULATION (R-10) AT FURRED CMU WALLS. INSTALL GYPSUM WALL BOARD (GWB) ON NEW STUD WALLS, 1ST AND 2ND FLOOR CEILING INFILLS, BASEMENT CEILING AND MECHANICAL BULKHEADS AS FOLLOWS; STANDARD INTERIOR WALLS, 1ST AND 2ND FLOOR CEILING INFILL - ½” GWB; BATHROOM AND KITCHEN WET WALLS - ½” MOISTURE RESISTANT (M.R.) GWB; TILE / BACKSPLASH LOCATIONS - ½” DUROCK; BASEMENT WALLS, CEILING AND MECHANICAL BULKHEADS - ½” M.R. GWB. ON 1ST AND 2ND FLOOR, INSTALL ½” GYPSUM BOARD DIRECTLY TO EXISTING JOISTS AT ALL CEILING INFILLS. INSTALL ¼” DUROCK OVER EXISTING WOOD SUBFLOOR AT KITCHEN AND 2ND FLOOR BATHROOM FLOOR AS TILE SUBSTRATE. INSTALL THIRTEEN (13) HINGED, HOLLOW CORE INTERIOR DOORS WITH STANDARD HARDWARE AND LOCKSETS. INSTALL SIX (6) HOLLOW CORE DOOR SLABS WITH BI-PASS HARDWARE AT CLOSETS. INSTALL KITCHEN CABINETS AND APPLIANCES. INSTALL CLOSET SHELVING SYSTEMS. INSTALL TOILET ACCESSORIES. INSTALL NEW STAIR HANDRAILS, ALL LEVELS. ALL WORK PER CODE. SEPERATE PERMITS WILL BE REQUESTED FOR MEP WORK. $60,000Nov 16, 2022

Violations

0

No violations on record.

Inspections

0

No inspections on record.