Baltimore City · 21229

521 OVERDALE RD

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$475,100
Land use
Residential (R)
Year built
1910
Last sale
Dec 14, 2022

Assessment

OwnerJAMES A. AND MARY JEAN BONOMO
Land useResidential (R)
Total assessment$475,100 (cycle 2026)
Last saleDec 14, 2022 — $519,900
Year built1910
ZoningR-1-E
Vacant

Permits

2
TypeDescriptionCostIssued
COM2024INSTALL (1) 52000 BTU FUEL-BURNING EQUIP AS PER CODE.$150Jan 8, 2024
COM2023SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: RE-LAY SECTION OF TILE ROOF AND REPLACE FAILING CHIMNEY CRICKET. *NO STRUCTURAL ALTERATIONS TO BE DONE, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE***************PER CHAP: ATP: DECK PREPARATION: 1. INSPECT ENTIRE ROOF DECK BEFORE INSTALLING NEW ROOFING. 2. RE-NAIL PROTRUDING ROOF NAILS AND CLEAN THE ROOF DECK FOR A SMOOTH SURFACE. 3. RE-NAIL LOOSE SHEATHING BOARDS TO RAFTERS WITH 8D COMMON NAILS. 4. REPLACE ROTTED LUMBER ON A TIME AND MATERIAL BASIS. 5. FURNISH AND INSTALL NEW 2'' X 4'' LUMBER AT HIPS AND RIDGES FOR ATTACHMENT OF HIP/RIDGE CAPS. UNDERLAYMENT: 1. CONSISTS OF TWO LAYERS OF #30 ASPHALT FELT PAPER. 2. SECURED TO THE DECK WITH 1'' PLASTIC CAP NAILS. FLASHING: EAVE DRIP EDGE FLASHING: .032 PRE-FINISHED WHITE ALUMINUM EAVE PROTECTION WITH CERTAINTEED WINTER GUARD ICE AND WATER SEAL. ICE AND WATER SEAL EXTENDS A MINIMUM OF 36'' UP THE ROOF SLOPE. THE EXISTING GUTTER NOT BEING REMOVED; FLASHING MUST BE NOTCHED. FRONT WALL APRON FLASHING: REMOVE OLD FLASHING, APPLY ICE AND WATER SEAL, AND INSTALL 20OZ COPPER FRONT WALL APRON FLASHING. FLASHING DIMENSIONS: MINIMUM 4 INCHES ON DECK, MINIMUM 3 INCHES HIGH ON THE VERTICAL FRONT WALL. ALL COPPER CORNER JOINTS WILL BE SOLDERED. SKYLIGHT CURBS: BUILD AND FLASH USING EPDM MEMBRANE. FIELD VERIFICATION OF SKYLIGHT DIMENSIONS BEFORE ORDERING. CURB DIMENSIONS: 25 ½'' X 49 ½''. INSTALLATION OF VELUX-TYPE FCM-2246 CURB-MOUNTED GLASS SKYLIGHT. PLUMBING VENT PIPES AND OTHER PENETRATIONS: INSTALL PREFABRICATED EPDM PIPE SEALS OR FORM FIELD FLASHING. USE UNCURED FLASHING AROUND PIPES AND STRUCTURAL STEEL TUBING. ALL WORK TO MATCH PLANS/INFORMATION/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES IT.**************** $13,577.64Dec 22, 2023

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;