20| Type | Status | Description | Cost | Issued | Contractor |
|---|---|---|---|---|---|
| Comm. Permit - Structure - Env Health | ISSUE | CONSTRUCT 3STY SCHOOL 131'X64'X43'=24,115SF. EROSION AND SEDIMENT CONTROL INSPECTION MUST BE SCHEDULED AND PASSED PRIOR TO ANY BUILDING ACTIVITY. ADDITIONAL WORK REQUIRES SEPARATE PERMIT. REFER TO C26-00263 FOR RETAINING WALL. | $7,000,000 | May 28, 2026 | — |
| Comm. Permit - Sprinkler | ISSUE | Install 6” and 4" fire line within 5’ of building. See C25-01768 for interior alts. Separate plumbing permit required. Please contact the Office of the Fire Marshal at 410-887-4880 to schedule an inspection. | $42,000 | May 14, 2026 | — |
| Comm. Permit - Retaining Wall | ISSUE | CONSTRUCT (2) CONCRETE RETAINING WALLS, 83LF & 128LF, 5’-11' IN HEIGHT, ON SIDE AND REAR OF SCHOOL PROPERTY. A 42” MINIMUM HEIGHT FENCE OR RAILING IS REQUIRED ABOVE RETAINING WALLS 4’ IN HEIGHT OR MORE, IF WALL IS WITHIN 2’ OF A WALKWAY, PATH, PARKING LOT, OR DRIVEWAY. MUST FOLLOW ALL RETAINING WALL CHECKLIST AND CONSTRUCTION PHASE SERVICE REQUIREMENTS. ESC DEVICES MUST BE INSTALLED AND INSPECTED BEFORE ANY WORK STARTS. | $195,000 | Mar 20, 2026 | — |
| Comm. Permit - Temporary Structures | ISSUE | Construct temporary restroom unit for classroom trailers. Permit expires at completion of C25-01768. 8' X 20' = 160sf. | — | Jan 31, 2026 | — |
| Comm. Permit - Temporary Structures | ISSUE | Construct temporary classroom trailers. Permit expires at completion of C25-01768. 38' X 23.5' = 893sf. | — | Jan 29, 2026 | — |
| Comm. Permit - Temporary Structures | ISSUE | Construct temporary classroom trailers. Permit expires at completion of C25-01768. 38' X 23.5' = 893sf. | — | Jan 29, 2026 | — |
| Comm. Permit - Storm Water | ISSUE | Storm Water Management for 0.45 acres drainage area. Permit expires two years from date of issue. NO CONSTRUCTION TO BEGIN UNTIL PRE-CONSTRUCTION MEETING. FAILURE TO COMPLY WILL RESULT IN PENALTIES. SCHEDULE YOUR PRE-CONSTRUCTION MEETING IN YOUR PORTAL. | $60,000 | Jan 22, 2026 | — |
| Comm. Permit - Grading | ISSUE | Grade 42,000sf for future school. Permit expires two years from date of issue. No construction to begin until pre-construction meeting. Failure to comply will result in penalties. Schedule your pre-construction meeting in your portal. | $750,000 | Jan 22, 2026 | Carson Gaines |
| Comm. Permit - Alteration | ISSUE | INTERIOR ALTERATIONS TO INCLUDE: DEMO & CONSTRUCT DRYWALL PARTITIONS, MTL STUD, CMU FOUNDATION WALLS, STAIRS, FINISHES. 50SF SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL WORK. | $10,000 | Oct 30, 2023 | — |
| Comm. Permit - New Structure/Shell | ISSUE | Construct outdoor pavilion 80'x40'x20'=3200sf per plans. | $200,000 | Jun 21, 2022 | — |
| Comm. Permit - New Structure/Shell * | ISSUE | ERECT TWO PRE-FABRICATED MODULAR TRAILERS USED | AS A CLASSROOM 40'X23'4"X12'=933SF PER PLANS. | REFER TO B000000 FOR RAMP. | — | Aug 11, 2021 | — |
| Comm. Permit - Alteration | ISSUE | EXT ALTS TO INSTALL 48KW FLUSH ROOF MOUNTED | SOLAR ARRAY 130 PANELS ON EX SCHOOL BLDG. | 2800SF. CERTIFICATE OF SOLAR PANEL INSTALLATION | TO BE SUBMITTED IN INSPECTORS AT TIME OF FINAL | INSPECTIONS. OK TO WAIVE DATA SHEETS:YAP. | — | Jan 7, 2019 | — |
| Comm. Permit - Storm Water * | ISSUE | STORM WATER MANAGEMENT 13.91AC DRAINAGE AREA | THIS PERMIT EXPIRES TWO YEARS FROM DATE OF | ISSUE | — | Apr 9, 2015 | — |
| Comm. Permit - Sprinkler * | ISSUE | NEW SPRINKLER SYSTEM IN NEW ADD'N TO SCHOOL. | 89 NEW SPRINKLERS | LARGEST PIPE SIZE 4" | B798468 | — | Jan 20, 2015 | — |
| Comm. Permit - Addition | ISSUE | CONSTRUCT ONE-STORY ADD'N ON SIDE OF EX SCHOOL | T/B LOUNGE AREA. 13'X14'=182SF. | SEALED CONST PLANS ON SITE, WAIVE PLANS-YAP | — | Jul 25, 2014 | — |
| Comm. Permit - Addition | ISSUE | CONSTRUCT ADDITION ON SIDE OF EX THEATRE | BUILDING TO EXPAND PROPOSED MEZZANINE AREA 10'X | 10' AND SEATING 64'2"X10'1"X36'=663SF. | — | Jul 1, 2014 | — |
| Comm. Permit - Addition | CLOSED | INT ALTS TO DEMO PORTION OF THEATRE BUILDING TO | INCLUDE:WALLS,CEILINGS,STAGE,STAIRS,DOORS, | FRAMES & ROOF & CONST SAME W/NEW RAISED ROOF, | MEZZANINE,FIXTURES & FINISHES 5340SF.CONST | ADD'N ON REAR/SIDE 78'X36'=1460SF.THIS PERMIT | CANCELS B798468 & EXPIRES 5/21/15,CHNG IN CONST | — | Jul 1, 2014 | — |
| Comm. Permit - Addition | CANCELLED | ALTS TO DEMO PART OF THEATRE BLDG TO INCLUDE | WALLS,CEILING,STAGE,STAIRS,DOORS,FRAMES & ROOF. | CONSTRUCT SAME W/NEW RAISED ROOF,NEW MEZZANINE | FIX,FIN 5240SF.CONST ADDN ON REAR/SIDE OF BLDG | 72'X35'=1,461SF(IRREG SHAPE).SEPARATE PERMIT | REQ'D FOR ANY ADDITIONAL WORK. | — | May 21, 2014 | — |
| Comm. Permit - Sign | ISSUE | (1) ILLUM F/S SCOREBOARD (LED) | 18'X25'=450SF | FRONT OF SIGN CAN NOT BE SEEN FROM ROAD | PER APPLICANT | — | Aug 15, 2013 | — |
| Comm. Permit - Addition | CLOSED | CONSTRUCT 1-STORY ADDITION ON SIDE OF EXISTING SCHOOL, TO BE USED AS: CLASSROOMS, FACILITY OFFICES, PER PLANS 108'X151'X25'2"=13,049SF : CONST 02 PLOT 9 R PLAT 0 DATA 0 ELEC YES PLUMB YES | — | Oct 18, 2002 | — |