Baltimore County · 21093

10807 TONY DR

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$1,604,000
Land use
Exempt Commercial (EC)

Assessment

Additional detail for this property — owner, sale history, and structure information — isn't available yet.

Land useExempt Commercial (EC)
Total assessment$1,604,000 (cycle 2026)

Permits

11
TypeStatusDescriptionCostIssuedContractor
Comm. Permit - New Structure/ShellISSUEAlt to complete B985485, framing final 6/17/22. "CONSTRUCT 1-STY SCHOOL BUILDING WITH CLASSRMS 4 ADA RESTROOMS, 2 ADMINISTRATIVE SPACES, A KITCHEN & SERVICE SPACE, LAUNDRY RM, JANITORS CLOSET, IT ROOM, & 4 STORAGE ROOMS PER PLANS 105'11"X53'3"X24'2-1/2"=5640SF. SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL WORK".$1,950,644Feb 14, 2023Jim Marino
Comm. Permit - SprinklerOPENProvide new wet system in on new building, and one wet system in an existing system, and wet and dry system in another existing building. INSTALL 254 SPRINKLER HEADS. LARGEST PIPE SIZE 4". RELATED PERMIT B985485.Jul 22, 2022Ken Gray
Comm. Permit - SprinklerISSUEIncoming Building Fire Line, largest pipe size 6". Refer to B985485 for construction of private school.Apr 21, 2022
Comm. Permit - New Structure/ShellISSUECONSTRUCT 1-STY SCHOOL BUILDING WITH CLASSRMS, | 4 ADA RESTROOMS, 2 ADMINISTRATIVE SPACES, A | KITCHEN & SERVICE SPACE, LAUNDRY RM, JANITORS | CLOSET, IT ROOM, & 4 STORAGE ROOMS PER PLANS | 105'11"X53'3"X24'2-1/2"=5640SF.Dec 29, 2021Mark Huppert
Comm. Permit - SprinklerISSUEINSTALL STUBIN FROM 5FT OUTSIDE OF BUILDING TO | ABOVE FLOOR SLAB. 6" LARGEST PIPE SIZE. REFER | TO B933533 FOR FIRE LINESep 27, 2017
Comm. Permit - Sprinkler *ISSUEINSTALL NEW FIRE SPRINKLER SYSTEM CONSISTING OF | 176 SPRINKLER HEADS, LARGEST PIPE SIZE 4" PER | PLANS IN AN EXISTING SCHOOL. SEE B908303 FOR | INT ALTS & ADDITION.May 26, 2017
Comm. Permit - SprinklerISSUEINSTALL 417LF OF 6" WATER LINE AND 78LF OF 4" | WATER LINE WITHIN 5' OF BLDG,2 HYDRANTS, | 3 8"X6" TAPPING SLEEVES,2-8"X4" TAPPING SLEEVES | 1-8"TO6" REDUCER,2-6"X6"X6" TEES,8-6" 1/8 BENDS | 1-6" 1/16 BEND,1-6" 1/4 BEND,1-4" 1/16 BEND, | 5-6" VALVES AND VAULTS,2-4" VALVES AND VAULTSMar 29, 2017
Comm. Permit - Sprinkler *ISSUEINSTALL 6" FIRE LINE STARTING AT 0+00 TO 155' | STOPPING 5' OUTSIDE OF BUILDING,TO START AT | EX VALVED AND VAULT.REFER TO B908303 AND | B908304 FOR CONST OF ADDITIONSMar 9, 2017
Comm. Permit - Addition *CLOSEDCONST ONE-STORY ADD'N INSET WITHIN EX SCHOOL | T/B KITCHEN EXTENSION 20'X9'6"=105SF. INT ALTS | TO DEMO & CONST WOOD STUD/DRYWALL PARTITIONS, | CEILING TILE/GRID, ADA RESTROOMS, HVAC SYSTEM | UPGRADE, FIXTURES & FINISHES; INSTALL EXHAUST | HOOD & KITCHEN EQUIPMENT. ALL WORK PER PLANS.Feb 27, 2017
Comm. Permit - Addition *CLOSEDREM PORTION OF BLDG FRM SIDE & CONST 1-STORY | ADD'N ON SIDE 72'6"X73'4"=5300SF. INT ALTS TO: | DEMO & CONST WOOD STUD/PARTNS,CEILING TILE/GRID | ADA RESTRMS, HVAC SYSTEM UPGRADE,FINISHES & | FIXTURES;INSTALL KITCN EQUIPMNT INCL EXHAUST | HOOD. 6936SF.ALSO USING TX ACCT #1700007579Feb 27, 2017
Comm. Permit - Alteration *ISSUEINT ALTS TO MAIN BUILDING TO INCLUDE: CODE | CORRECTION WORK FOR REPAIR OF SECOND FLOOR | EGRESS, DOORS AND WINDOWS. 251SF. ALL WORK PER | PLANS. SEPARATE PERMIT REQ'D FOR ANY ADD'L WORK | PLANS WAIVED. JBSep 22, 2014