Baltimore County · 21152

38 LOVETON CIR

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$6,941,300
Land use
Industrial (I)

Assessment

Additional detail for this property — owner, sale history, and structure information — isn't available yet.

Land useIndustrial (I)
Total assessment$6,941,300 (cycle 2026)

Permits

17
TypeStatusDescriptionCostIssuedContractor
Comm. Permit - AlterationISSUEExterior alterations to include: Remove and replace roof in kind on existing commercial building. 28352SF per plans. Any additional work will require a separate permit application.$750,000Mar 9, 2026
Comm. Permit - AlterationISSUEExterior alteration to erect steel structure to support dryer pad with 2 sets of stairs. 1824sf. Separate permit required for any additional work.$350,000Dec 5, 2025
Comm. Permit - New Structure/ShellISSUESaw cut asphalt and install footings and install concrete pad on corrugated steel pans as base for and erect steel structure for dryer per engineer's drawings 28'x43'=1,204SF. Separate permit required for any additional work. Erosion and sediment control inspection must be scheduled and passed prior to any building activity.$280,000May 5, 2025
Comm. Permit - AntennasISSUERemove and replace one microwave dish antenna and upgrade ancillary equipment as per plans. No change in height. 142'hgt. MFG instructions & structural engineering letter attached.$6,000Apr 3, 2024
Comm. Permit - AntennasISSUEInstall 5 Antennas on an existing monopole for the internal use of upgrading BG & E internal Communications. 150' high.$22,000Mar 13, 2023
Comm. Permit - SprinklerISSUEFireline Corporation has been contracted to design, provide, and install a new NOVEC 1230 Fire Suppression System for the server room at Teledyne Energy Systems. Largest pipe size 1.25".$25,090Dec 10, 2022
Comm. Permit - AntennasISSUERemove (3) Antennas; remove (6) Coax Cables; relocate (3) antennas; relocate (3) radios; install mount modification; install (3) new antennas. Tower height 152'.Oct 31, 2022John Cowden
Comm. Permit - SprinklerISSUEReroute existing wet lines out of existing office space and add new preaction system to same space. INSTALL 2 SPRINKLER HEADS. LARGEST PIPE SIZE 1.5". METER SIZE 6".May 24, 2022
Comm. Permit - AntennasISSUEInstall (3) new antennas (1 per sector) on new antenna platform mount with (6) RRHs (2 per sector) on (3) new double-z brackets (1 per sector), (1) OVP Device, and (1) Hybrid cable on existing tower. Install metal platform for equipment cabinet and ice bridge on ground below tower.Feb 27, 2022
Comm. Permit - TanksCLOSEDREMOVAL OF 1 (ONE) 4000 GALLON UNDER-GROUND | DIESEL STORAGE TANK. NO REPLACEMENT. GROUND | WATER MANAGEMENT FORM ATTACHEDApr 19, 2021
Comm. Permit - SprinklerISSUERELOCATE 1 & ADD 16 SPRINKLER HEADS, LARGEST | PIPE SIZE 1" PER PLANS. SEE B847400 FOR EXT ALTJun 17, 2015
Comm. Permit - SprinklerISSUEADD 9 & RELOCATE 21 SPRINKLER HEADS ON WET | SYSTEM; DEMO 57 SPRINKLER HEADS ON DRY SYSTEM, | LARGEST PIPE SIZE 1-1/2" PER PLANS. SEE B847400 | FOR ALTERATIONS.Sep 25, 2014
Comm. Permit - AlterationCLOSEDWALL CONSTRUCTION TO INSTALL ROLL-UP DOOR. INT | ALTS TO REMOVE SLAB CAP, DEMO & CONST MTL STUD/ | DRYWALL PARTITIONS, DOORS, HVAC, ROOF TOP UNITS | CEILING TILE/GRID, FINISHES & FIXTURES PER PLAN | 3500SF. SEPARATE PERMIT REQD FOR ANY ADDL WORK. | NO CHG IN USE OR FOOTPRINT:LW.Jun 30, 2014
Comm. Permit - AlterationISSUEINT ALTS TO DEMO ONLY: PARTIAL FIRST FLOOR AND | PARTIAL ROOF. 2000SF. SEPARATE PERMIT REQ'D FOR | ANY ADD'L WORK. SEALED PLANS ON SITE, WAIVE | PLANS-ALBMay 15, 2014
Comm. Permit - AntennasCLOSEDREPLACE 12 EXISTING ANTENNAS W/9 NEW ANTENNAS. | NO CHANGE IN HEIGHT. NO GROUND WORK. AS PER | PLANS AS PER CODE. OK TO WAIVE PLANS:YAP. KEEP | SET OF SEALED PLANS ON SITE.Mar 31, 2014
Comm. Permit - AdditionCLOSEDCONSTRUCT ADDITION ON REAR OF AN EXISTING COMMERCIAL BUILDING, TO BE USED AS MANUFACTURING WITH SAFETY SHOWER AREA PER PLANS 120'X48'3"X20'=5760SF. : CONST 02 PLOT 9 R PLAT 0 DATA 3 ELEC YES PLUMB YESMar 10, 2002
Comm. Permit - GradingCLOSEDGRADE 11,600SF FOR ENERGY SYSTEMS EXPANSION. PERMIT EXPIRES TWO YEARS FROM ISSUE DATE. : CONST 00 PLOT 8 R PLAT 0 DATA 0 ELEC NO PLUMB NOJan 29, 2002

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.