Baltimore County · 21093
9515 DEERECO RD
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $14,169,567
- Land use
- Commercial (C)
Assessment
Additional detail for this property — owner, sale history, and structure information — isn't available yet.
| Land use | Commercial (C) |
|---|---|
| Total assessment | $14,169,567 (cycle 2026) |
Permits
25| Type | Status | Description | Cost | Issued | Contractor |
|---|---|---|---|---|---|
| Comm. Permit - Antennas | ISSUE | Change in construction. Expiration date 5/16/2026. AT&T is modifying an existing rooftop cell site. Removing 7 antennas, and 12 RRHs. Installing 7 new antennas and 16 RRHs. Upgrading antenna mounts. AT&T is not increasing the height (148'). This permit cancels and replaces issued permit C25-00227. Change in construction. Expiration date 5/16/2026. | $26,000 | Jun 2, 2026 | — |
| Comm. Permit - Alteration | ISSUE | INTERIOR ALTERATIONS TO INCLUDE: DRYWALL PARTITIONS, MTL-STUD, CEILING TILE & GRID, BREAK RM, MILLWORK, FIXTURES AND FINISHES, HVAC. 1,809SF SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL WORK. | $80,000 | Aug 25, 2025 | — |
| Comm. Permit - Alteration | ISSUE | Interior alts to demo and construct drywall partitions, metal-stud, ceiling grid and tile, HVAC, ADA restroom, fixtures and finishes per plans. 3850sf. Separate permit required for any additional work. | $295,000 | Jul 11, 2025 | — |
| Comm. Permit - Sprinkler | ISSUE | NFPA 13 system. Relocate 9 sprinkler heads in commercial space. No Plans Required. Largest pipe size 1”, meter size 6", light hazard occupancy. See C25-00853 for interior alts. Please contact the Office of the Fire Marshal at 410-887-4880 to schedule an inspection. | $500 | Jun 19, 2025 | — |
| Comm. Permit - Sprinkler | OPEN | NFPA 13 system. Add 41 sprinkler heads in commercial space per plans, largest pipe size 1.5”, meter size 4", light hazard occupancy. See C25-00224 for interior alts. Please contact the Office of the Fire Marshal at 410-887-4880 to schedule an inspection. | $8,433 | May 29, 2025 | — |
| Comm. Permit - Sprinkler | ISSUE | NFPA 13 system. Relocate 7 sprinkler heads. Largest pipe size 1", meter size 6", related permit C23-02346. No Plans required per DMC. | $1,800 | Jan 9, 2024 | — |
| Comm. Permit - Antennas | ISSUE | Remove all DC/Fiber runs, Remove all DC2s, Add 3 Fiber Trunks, Add 4 DC9s, Add 12 DC Trunks, Remove 9 Antennas, Remove 6 RET Motors, Remove 6 TMAs, Remove 6 RRHs, Remove 6 Diplexers, Add 12 Antennas, Add 10 RRHs. | — | Sep 19, 2022 | Brad Roth |
| Comm. Permit - Antennas | ISSUE | Change out antennas and existing equipment on an existing wireless installation. Removing 12 antennas, 9 radios and 3 coax and replacing with 12 antennas and 9 radios on existing rooftop. All other equipment to stay the same | — | Jun 29, 2022 | TELTRONIC TOWERS INC |
| Comm. Permit - Sprinkler | OPEN | relocate 3 sprinkler heads, light hazard. Relocate 3 sprinkler heads. Largest pipe size 1". Meter size 6". Related permit C21-01499. | — | Jan 29, 2022 | Larry Davis |
| Comm. Permit - Antennas | ISSUE | REMOVE (3) ANTENNAS AND REPLACE WITH (3) | ANTENNAS, REMOVE AND REPLACE (3) TMA'S AND | INSTALL (3) RRU'S, REMOVE (1) EX CABINET AND | REPLACE WITH (2) SUPPORT CABINETS. | S.P.O.S ALB | — | Sep 23, 2020 | — |
| Comm. Permit - Antennas | ISSUE | REMOVE & REPLACE (3), REM & REPLACE (3) RRU'S, | REMOVE & REPLACE (3) TMA'S, INSTALL (3) HYBRID | CABLES. S.P.O.S-YAP-CONST PLANS WAIVED. | ON EXISTING ROOFTOP MOUNT. | — | May 29, 2019 | — |
| Comm. Permit - Addition | ISSUE | CONSTRUCT MOTORIZED PERGOLA ATTACHED TO FRONT | OF EXISTING RESTAURANT 42'X38'X10'7"=1600SF | PER PLANS. SEPARATE PERMIT REQ'D FOR ANY ADD'L | WORK. | — | Mar 15, 2019 | — |
| Comm. Permit - Antennas | CLOSED | REMOVE & REPLACE 6 ANTENNAS ON EXISTING ROOFTOP | WITH UPGRADE TO RELATED ANCILLARY EQUIPMENT AS | PER PLANS. NO CHG IN HGHT. OK TO WAIVE PLANS: | ALB. KEEP SET OF SEALED PLANS ON SITE. | — | Dec 12, 2018 | — |
| Comm. Permit - Addition | ISSUE | ALTS TO EXISTING CANOPY TO REPLACE AS NEEDED | AND CONST NEW CANOPY UNDER EXISTING CANOPY ON | FRNT OFFICE BLDG 50'X12'=600SF SEPARATE PERMIT | REQD FOR ANY ADDL WK. REFER TO B874611 FOR | ADDL WORK. OK TO WAIVE PLANS:YAP KEEP SEALED | SET ON SITE FOR INSPECTORS. | — | Nov 28, 2018 | — |
| Comm. Permit - Alteration | CLOSED | ALTERATION TO COMPLETE FOR FINAL OCCUPANCY, | FLOORS 3 AND 5 THRU 10 ONLY. FRAMING DATES FOR | FLOORS:3RD-4/13/17, 5TH-9/21/15, 6TH-11/23/15, | 7TH-3/11/16, 8TH-6/3/16, 9TH-10/5/16, 10TH- | 1/31/17. ELECTRIC AND PLUMBING HAVE BEEN | FINALED. REFER TO B874611. | — | Jun 20, 2017 | — |
| Comm. Permit - Antennas | ISSUE | REMOVE THREE (3) & INSTALL THREE (3) PANEL | ANTENNAS ON BUILDING ROOFTOP PER PLANS. NO | CHANGE IN HEIGHT. KEEP SEALED CONSTRUCTION PLAN | ON SITE; WAIVE PLANS:YAP.SITE ID:BAN022A. | — | Dec 6, 2016 | — |
| Comm. Permit - Antennas | CLOSED | REMOVE (3) AND REPLACE (3) ANTENNAS ON | EXISTING TELECOMMUNICATIONS FACILITY ON | ROOFTOP SITE. KEEP SET OF SEALED & SIGNED | CONSTRUCTION PLANS ON SITE PER SLW-OK TO | WAIVE PLANS PER SLW. | — | Aug 23, 2016 | — |
| Comm. Permit - Antennas | ISSUE | REMOVE 14 EX ANTENNAS AND ADD 12 NEW ANTENNAS | AND OTHER ASSOCIATED WORK. NO GROUND WORK. | ON EXISTING TOWER. NO CHANGE IN HEIGHT. | SEALED CONST PLAN TO BE ON SITE, PLAN WAIVED: | YAP | — | Feb 17, 2016 | — |
| Comm. Permit - Alteration | ISSUE | INT ALTS TO MEZZANINE & LOBBY FL 1-10 INCLUDES: | METAL STUD DRYWALL PARTITIONS, HVAC, CEILING | TILE/GRID, FINISHES & FIXTURES PER PLANS-5600SF | ALTS TO EXISTING CANOPY TO REPLACE AS NEEDED & | CONSTRUCT NEW CANOPY UNDER EXISTIN CANOPY ON | FRONT OF OFFICE BLDG-50'X12'=600SF. | — | Jun 16, 2015 | — |
| Comm. Permit - Antennas | ISSUE | REPLACE 9 EXISTING ANTENNAS W/12 NEW ANTENNAS | ON EXISTING 130' BUILDING (ROOF TOP). NO CHANGE | IN HEIGHT. AS PER CODE AND PER PLANS. OK TO | WAIVE PLANS:YAP. KEEP SET OF SEALED PLANS ON | SITE. | — | Jan 6, 2015 | — |
| Comm. Permit - Antennas | ISSUE | INSTALL 3 ANTENNAS ON ANCILLARY DEVICES ON | ROFFTOP OF EXISTING BUILDING. S.P.O.S. ALB | WAIVE PLANS | — | Dec 12, 2014 | — |
| Comm. Permit - Antennas | ISSUE | REMOVE (3) AND REPLACE (3) ANTENNAS ON | ROOFTOP TELECOMMUNICATIONS SITE. KEEP SET OF | SEALED AND SIGNED CONSTRUCTION PLANS ON SITE- | OK TO WAIVE PLANS PER SLW. | — | Nov 22, 2013 | — |
| Comm. Permit - Antennas | ISSUE | REPLACE 9 EXISTING ANTENNAS W/ 12 NEW ANTENNAS | ON EXISTING ROOFTOP AS PER PLANS, AS PER CODE. | NO CHANGE IN HEIGHT. OK TO WAIVE PLANS:ALB. | KEEP SET OF SEALED PLANS ON SITE. | — | Aug 7, 2013 | — |
| Comm. Permit - Addition | CLOSED | CONSTRUCT ONE STY ADDITION ONTO SIDE OF EX RESTAURANT FOR ADD'L SEATING. CONSTRUCT OUTDOOR DECK W/CANOPY ROOF. SEPARATE PERMIT REQ'D FOR ANY ADD'L WORK. 43'8"X93'4"X15'4"=4071SF DATA SHTS WILL BE SUBMITTED PRIOR TO PERMIT APPROVAL PER SLW. : CONST 02 PLOT 9 R PLAT 0 DATA 3 ELEC YES PLUMB YES | — | Jun 17, 2002 | — |
| Comm. Permit - Alteration | CLOSED | INT ALTS TO INCLUDE: DEMO & CONSTRUCT METAL | STUD & DRYWALL PARTITIONS, CEILING GRID & TILE, | HVAC, FIXTURES & FINISHES PER PLANS 1807SF. | SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL | WORK. KEEP SEALED CONSTRUCTION PLANS ON SITE. | WAIVE PLANS:SLW. | — | — | — |