6| Type | Status | Description | Cost | Issued | Contractor |
|---|---|---|---|---|---|
| Comm. Permit - Alteration | ISSUE | Interior alterations to include: demo and construct metal stud and drywall partitions, ceiling grid and tile, ADA restrooms, millwork, fixtures and finishes to create more marketable space and create smaller office space. All work per plans 20,000SF. Building constructed in 1982. Separate permit required for any additional work. | $750,000 | Feb 14, 2024 | — |
| Comm. Permit - Alteration | ISSUE | Exterior alterations to include: demolition of the existing addition that was added for the last tenant to use as refrigerated storage, a covered walkway/loading dock, and drive-in ramp. The existing 8'-0" x 8'-0" openings that will be exposed by the demolition will be fitted with overhead doors and dock bumpers. A new galvanized steel staircase will be added where the previous ramp was removed. There is no interior work under this permit. Separate permit required for any additional work. 10 | $500,000 | Jan 27, 2024 | — |
| Comm. Permit - Sign | ISSUE | Replace existing signs with new signs (2 wall signs and 1 directional sign) | — | Aug 31, 2022 | David Rand |
| Comm. Permit - Sprinkler | ISSUE | Install 51 heads, largest pipe size-2",Add new drop down center fed tree system above the new mixing area for code compliant ordinary hazard coverage. reinstall 7 demolished branch lines in their previous locations in order to maintain existing ordinary hazard coverage. all work performed under NFPA13-2016. No fire pump. max spacing for all areas 120 ft². Reliance Fire Protection | — | Nov 17, 2021 | — |
| Comm. Permit - Alteration * | ISSUE | INTERIOR ALTERATIONS INCLUDE:COOLER BOX FOR | NEW MIXING ZONE, CEILING TILE/GRID, HVAC/DUCT | WORK, INSTALL MANUFACTURING EQUIPMENT. 3700SF | SEPARATE PERMIT REQ'D FOR ANY ADD'L WORK. | SEALED PLAN ON SITE CONST PLAN WAIVED/YAP | — | Aug 26, 2021 | — |
| Comm. Permit - Addition | CLOSED | CONSTRUCT 1STY ADDITION ON REAR OF EX BLDG. TO BE USED AS FREEZER.SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL WORK. 60'4"X41'3"=2,479SF : CONST 2 PLOT 9 R PLAT DATA 3 ELEC YES PLUMB YES | — | Jul 20, 2002 | — |