Baltimore County · 21219

7030 TRADEPOINT AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$89,643,500
Land use
Industrial (I)

Assessment

Additional detail for this property — owner, sale history, and structure information — isn't available yet.

Land useIndustrial (I)
Total assessment$89,643,500 (cycle 2026)

Permits

29
TypeStatusDescriptionCostIssuedContractor
Comm. Permit - AlterationISSUEInterior alteration to change conveyor system from floor-mount to ceiling-hung in existing warehouse per plans and structural report. 9000sf. Any additional work requires separate permit.$236,000Jul 1, 2026
Comm. Permit - AlterationISSUEInterior alterations to include: Install new 54 bays of case storage racking. Separate permit required for any additional work. 2700SF See C25-00823 Addition$111,813Jan 2, 2026
Comm. Permit - AlterationISSUEInterior alterations to include: Relocate 189 bays of pallet storage rack & install new 1,246 bays of case storage rack. Separate permit required for any additional work. 163,000SF$2,579,971Nov 3, 2025
Comm. Permit - AlterationISSUECONSTRUCT DRYWALL PARTITIONS, MTL-STUD, CEILING TILE AND GRID, ADA RESTROOMS, HVAC AND DUCT WK, FIXTURES AND FINISHES. 1,003SF SEPARATE PERMIT REQUIRED FOR ANY ADDITIONAL WORK.$75,000Oct 24, 2025
Comm. Permit - SprinklerISSUENFPA 13 system. Add 9 sprinkler heads in office space [No Plans Required]. Largest pipe size – 2”, light hazard occupancy. Meter size 8". See C25-00976 for interior alts. Please contact the Office of the Fire Marshal at 410-887-4880 to schedule an inspection.$5,000Sep 1, 2025
Comm. Permit - AdditionISSUEConstruct exterior metal canopy attached to side of building 185'x4'=740sf. Alterations to include: Installation of additional 13 dock doors to be installed where future knock outs were already planned. This includes the dock doors, dock levelers, and all associated utilities 1690sf. All work per plans. Separate permit required for any additional work.$700,000May 17, 2025
Comm. Permit - AlterationISSUEInterior alterations to include: Remove, replace and upgrade material handling conveyance system in existing warehouse, 300000sf per plans. Separate permit required for any additional work.$5,560,000Apr 23, 2025
Comm. Permit - SprinklerISSUEModify existing fire sprinkler system to accommodate the tenant modifications being made to the first floor office space. Install 87 sprinkler heads. Largest pipe size 1". Meter size 4". Related permit C21-01246Feb 11, 2022
Comm. Permit - SprinklerISSUEContractor: Absolute Fire Protection, Inc. SCOPE: Alter the existing fire sprinkler system throughout the Under Armour ODH Archive Storage suite. (44 SPRINKLER HEADS) Largest pipe size 1 1/2".Dec 9, 2021Jessica Hickman
Comm. Permit - AlterationISSUEINTERIOR ALTERATIONS TO INSTALL STORAGE RACKS | IN WAREHOUSE. 43,569SF. SEPARATE PERMIT REQ'D | FOR ANY ADD'L WORK.Jun 10, 2020
Comm. Permit - AlterationISSUEINTERIOR ALTERATIONS TO INCLUDE: INSTALL | RACKING SYSTEM IN EXISTING WAREHOUSE PER PLANS | 50,735SF. SEPARATE PERMIT REQUIRED FOR ANY | ADDITIONAL WORK.Apr 22, 2020
Comm. Permit - AdditionISSUEINTERIOR ALTERATIONS TO INCLUDE: DEMO | STOREFRONT WALL AND CONSTRUCT STAIRCASE FOR | WAREHOUSE PER PLANS 21'X9'1"X19'=45SF | S.P.O.S ALBMar 17, 2020
Comm. Permit - SprinklerISSUEADD 42 SPRINKLER HEAD & RELOCATE 60 HEADS IN | OFFICE SPACE PER NFPA13, LARGEST PIPE SIZE - 1" | SEE B960481 FOR INT ALTSAug 21, 2019
Comm. Permit - AlterationCLOSEDINT ALT TO INCLUDE: DEMO AND CONST MTL STUD/ | DRYWALL PARTITIONS, CEILING TILE/GRID, HVAC/ | DUCT WK, ROOFTOP UNITS, ADA RESTRMS, MILLWORK, | FINISHES AND FIXTURES PER PLANS. 21,202SF. | SEPERATE PERMIT REQD FOR ANY ADDL WORKJul 23, 2019
Comm. Permit - SprinklerISSUEADD 28 SPRINKLER HEADS PER NFPA 13, LARGEST | PIPE SIZE 2-1/2" PER PLANS.Jul 26, 2018
Comm. Permit - SprinklerISSUEADD (5) UPRIGHT SPRINKLER HEADS TO EXISTING | SPRINKLER SYSTEM. LARGEST PIPE SIZE 1 1/2". | FIRE PUMP. NO PLANS REQ'D. REFER TO B946247.Jul 13, 2018
Comm. Permit - AlterationCLOSEDINT ALTS TO EX SHELL BLDG TO CONSTRUCT ENCLOSED | FIRE RATED 4-STORY STAIR TOWER AND OPEN STAIR | THAT EACH CONNECT TO THE PICK MODULE 848SF PER | PLANS. SEPARATE PERMIT REQ'D FOR ANY ADD'L WORK | OK TO WAIVE DATA SHEET: YAPMay 29, 2018
Comm. Permit - AlterationCLOSEDINTERIOR ALTERATIONS TO INSTALL VERTICAL | RECIPROCATING CONVEYOR (4 LEVELS) IN | WAREHOUSE. 60SF. SEPARATE PERMIT REQ'D FOR ANY | ADD'L WORK. SEALED CONST PLAN ON SITE-YAP- | CONST PLAN WAIVE.Apr 12, 2018
Comm. Permit - AlterationCLOSEDINT ALTS TO SHELL BLDG TO INCLUDE: EXIT DOORS, | CROSSOVER STAIRS PER PLANS 2,300SF.SEPARATE | PERMIT REQ'D FOR ANY ADD'L WORK.Apr 12, 2018
Comm. Permit - SprinklerISSUEINSTALL SPRINKLER SYSTEM UNDER CONVEYORS | 692 HEADS, LARGEST PIPE SIZE 2-1/2" | INSTANT PERMIT AND PRE-INSPECTION BY CHARLES | RUTH. | REFER TO P943304, B938300, B939834, B940743 AND | B941572 FOR ADD'L SPRINKLER WORKJan 24, 2018
Comm. Permit - SprinklerISSUEINSTALL PICK MODULE SPRINKLER SYSTEM CONSISTING | OF 3,105 UPRIGHT K8 SPRINKLER HEADS, LARGEST | PIPE SIZE 4" PER PLANS. SEE B938300 FOR | ADDITIONAL WORK.Oct 30, 2017
Comm. Permit - SprinklerISSUEINSTALL 619 SPRINKLER HEADS, LARGEST PIPE SIZE | 2-1/2" PER PLANS: 1)HOSE VALVE SYSTEM; 2)OFFICE | MDF ROOM PRE-ACTION SYSTEM (4 HEADS); | 3)2ND FLOOR OFFICE-UNFINISHED SPACE(615 HEADS).Oct 5, 2017
Comm. Permit - SprinklerISSUEINSTALL: SPRINKLERS IN THE OFFICE TI (348) | K 5.6 SEMI REC PENDENT IN OFFICE. | REFER TO C/S A760251 FOR PREVIOUS | PAYMENT PER KLL & LWS | L.S.Sep 20, 2017
Comm. Permit - SprinklerISSUETHIS PERMIT IS LIMITED TO THE WAREHOUSE IT | SPRINKLERS, THE PRODUCTION MEZZANINE AND FIRE | PUMP.TOTAL OF 1588 SPRINKLER.PER NFPA 13 AND | NFPA 20.SEE B934304 FOR ADDITIONAL SPRINKLER | PERMIT.Sep 1, 2017
Comm. Permit - AlterationCLOSEDINT ALTS TO INCLUDE: INSTALL RACKING SYSTEMS | IN STORAGE FACILITY PER PLANS 181,267SF. | REFER TO B928490 FOR SHELL BUILDING. SEPARATE | PERMIT REQUIRED FOR ANY ADDITIONAL WORK. | WAIVE DATA SHEETS:YAP.Jul 19, 2017
Comm. Permit - SprinklerISSUETHIS PERMIT IS LIMITED TO THE OVERHEAD ESFR | SPRINKLERS ONLY.THIS PERMIT DOES NOT GUARANTEE | ANY OTHER SPRINKER PERMITS WILL BE ISSUED. | DESIGN & INSTALL 33 COMPLETE ESFR K22 @ 50 PSI | SPRINKLER SYSTEMS PER NFPA 13 & LOCAL REQRMNTS | LARGEST PIPE SIZE = 10"May 19, 2017
Comm. Permit - AlterationCLOSEDCBCA.INT ALTS TO CONSTRUCT MTL STUD/DRYWALL | PARTITIONS,ADA RESTRMS,CEILING TILE/GRID, | GYPSUM BOARD CEILING,HVAC,12" HIGH CHAINLINK | FENCE,FIXTURES/FINISHES PER PLANS.SEPARATE | PERMIT REQ'D FOR ANY ADDITIONAL WORK.9637SF | NO CHANGE IN USE/SETBACKS/PARKINGMar 22, 2017
Comm. Permit - New Structure/ShellCLOSEDERECT SHELL BLDG 670'X1850'X45'=1,348,500SF | SEPARATE PERMIT REQD TO COMPLETE INTERIOR. | ISSUANCE OF THIS PERMIT DOES NOT GUARANTEE | ISSUANCE TO SUBSEQUENT PERMITS BY BALTIMORE | COUNTY. CBCA.Feb 2, 2017
Comm. Permit - AlterationISSUEINT ALTS TO INCLUDE:DEMO & CONSTRUCT DEMISING WALL, DRYWALL PARTITONS, MTL-STUD, CEILING TILE & GRID, MILL WORK, BREAKRM, HVAC & DUCT WK, FIXTURES AND FINISHES. 7,938 sf. Separate permit req'd for any additional work.$587,850Donald Jones