Baltimore City · 21202
8 E MADISON ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $867,600
- Land use
- Residential (R)
- Year built
- 1900
- Last sale
- Jun 10, 2020
Assessment
| Owner | SCHREIER, BENJAMIN J |
|---|---|
| Land use | Residential (R) |
| Total assessment | $867,600 (cycle 2026) |
| Last sale | Jun 10, 2020 — $710,000 |
| Year built | 1900 |
| Zoning | OR-2 |
| Vacant | — |
Permits
5| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2022 | REBUILD DAMAGED MASONRY WALLS ON NORTH AND EAST SIDE OF CARRIAGE HOUSE AS NEEDED. HISTORIC BRICK TO BE RECLAIMED. ALL NEW MORTAR MUST MATCH HISTORIC MORTAR IN COLOR, SIZE, TEXTURE, MATERIAL COMPOSITION, AND JOINT PROFILE. FURNISH & INSTALL TWO NEW CARRIAGE HOUSE DOORS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS******** AS PER CHAP: REBUILD DAMAGED MASONRY WALLS ON NORTH AND EAST SIDE AS NEEDED. HISTORIC BRICK TO BE RECLAIMED ALL NEW MORTAR MUST MATCH HISTORIC MORTAR IN COLOR, SIZE, TEXTURE, MATERIAL COMPOSITION, AND JOINT PROFILE. FURNISH & INSTALL TWO NEW CARRIAGE HOUSE DOORS ALL WORK TO MATCH INFORMATION PROVIDED TO CHAP. | $20,000 | May 10, 2022 |
| COM2021 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2020-69679:ATP PER CHAP:FURNISH AND INSTALL NEW TPO ROOF ON MAIN HOUSE. REPAIR EXISTING CORNICE AND BUILT IN GUTTER ON MAIN HOUSE. REPAIR EXISTING FRONT WOOD PORTICO. STRIP, RESTORE, AND PAINT 23 WINDOWS (FIRST AND SECOND FLOOR WINDOWS ON THE FRONT AND ALLEY ELEVATIONS). PAINT 19 ADDITIONAL WINDOWS. ANY WOOD REPLACEMENT AT WINDOWS TO MATCH EXISTING DETAILING AND DIMENSIONS. WINDOWS TO BE PAINTED TO MATCH EXISTING. INSTALL 35 ALLIED STORM WINDOWS. STORMS TO MATCH PAINT OF EXISTING WINDOWS. REPOINT EXISTING EAST ELEVATION OF MAIN HOUSE INCLUDING STONE FOUNDATION. REPOINT FRONT FAÇADE OF MAIN HOUSE AS NEEDED. REPOINT CARRIAGE HOUSE. REBUILD REAR CHIMNEY OF MAIN HOUSE TO MATCH EXISTING. REBUILD ALLEY WALL WHERE BOWED. ANY BRICK REPLACEMENT MUST USE HISTORICALLY MATCHING BRICK. MORTAR TO MATCH HISTORIC IN COLOR, TEXTURE, COMPOSITION, AND TOOLING. REMOVE DAMAGED SHUTTERS AND STORE IN BASEMENT. ALL WORK TO MATCH INFORMATION PROVIDED TO CHAP.) Original Permit Description:(COM2020-69679) ATP PER CHAP:FURNISH AND INSTALL NEW TPO ROOF ON MAIN HOUSE. REPAIR EXISTING CORNICE AND BUILT IN GUTTER ON MAIN HOUSE. REPAIR EXISTING FRONT WOOD PORTICO. STRIP, RESTORE, AND PAINT 23 WINDOWS (FIRST AND SECOND FLOOR WINDOWS ON THE FRONT AND ALLEY ELEVATIONS). PAINT 19 ADDITIONAL WINDOWS. ANY WOOD REPLACEMENT AT WINDOWS TO MATCH EXISTING DETAILING AND DIMENSIONS. WINDOWS TO BE PAINTED TO MATCH EXISTING. INSTALL 35 ALLIED STORM WINDOWS. STORMS TO MATCH PAINT OF EXISTING WINDOWS. REPOINT EXISTING EAST ELEVATION OF MAIN HOUSE INCLUDING STONE FOUNDATION. REPOINT FRONT FAÇADE OF MAIN HOUSE AS NEEDED. REPOINT CARRIAGE HOUSE. REBUILD REAR CHIMNEY OF MAIN HOUSE TO MATCH EXISTING. REBUILD ALLEY WALL WHERE BOWED. ANY BRICK REPLACEMENT MUST USE HISTORICALLY MATCHING BRICK. MORTAR TO MATCH HISTORIC IN COLOR, TEXTURE, COMPOSITION, AND TOOLING. REMOVE DAMAGED SHUTTERS AND STORE IN BASEMENT. ALL WORK TO MATCH INFORMATION PROVIDED TO CHAP. | — | Dec 10, 2021 |
| COM2021 | SCOPE OF WORK: ALTERATIONS TO INCLUDE: ABANDON IN PLACE (1) 1,000 GALLON UNDERGROUND HEATING OIL TANK, LOCATED IN FRONT OF PROPERTY. WILL COMPLY WITH COMAR 26.10 AND NFPA30, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *PROPERTY IS TO REMAIN SAFE AND SECURED | $2,700 | May 4, 2021 |
| COM2020 | ATP PER CHAP:FURNISH AND INSTALL NEW TPO ROOF ON MAIN HOUSE. REPAIR EXISTING CORNICE AND BUILT IN GUTTER ON MAIN HOUSE. REPAIR EXISTING FRONT WOOD PORTICO. STRIP, RESTORE, AND PAINT 23 WINDOWS (FIRST AND SECOND FLOOR WINDOWS ON THE FRONT AND ALLEY ELEVATIONS). PAINT 19 ADDITIONAL WINDOWS. ANY WOOD REPLACEMENT AT WINDOWS TO MATCH EXISTING DETAILING AND DIMENSIONS. WINDOWS TO BE PAINTED TO MATCH EXISTING. INSTALL 35 ALLIED STORM WINDOWS. STORMS TO MATCH PAINT OF EXISTING WINDOWS. REPOINT EXISTING EAST ELEVATION OF MAIN HOUSE INCLUDING STONE FOUNDATION. REPOINT FRONT FAÇADE OF MAIN HOUSE AS NEEDED. REPOINT CARRIAGE HOUSE. REBUILD REAR CHIMNEY OF MAIN HOUSE TO MATCH EXISTING. REBUILD ALLEY WALL WHERE BOWED. ANY BRICK REPLACEMENT MUST USE HISTORICALLY MATCHING BRICK. MORTAR TO MATCH HISTORIC IN COLOR, TEXTURE, COMPOSITION, AND TOOLING. REMOVE DAMAGED SHUTTERS AND STORE IN BASEMENT. ALL WORK TO MATCH INFORMATION PROVIDED TO CHAP. | $50,000 | Jul 22, 2020 |
| COM2020 | INSTALL (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | $6,000 | Jul 2, 2020 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Maintenance StructureJul 9, 2026 · 78 m · 829 N CHARLES ST
- violation: HCD-Maintenance StructureJul 5, 2026 · 98 m · 817 SAINT PAUL ST
- violation: BC 123.8.2Jun 30, 2026 · 105 m · 809 SAINT PAUL ST
- violation: BC 123.8.2Jun 30, 2026 · 105 m · 809 SAINT PAUL ST
- violation: BC 123.8.2Jun 30, 2026 · 116 m · 904 SAINT PAUL ST
- violation: HCD-Sanitation PropertyJun 30, 2026 · 129 m
- violation: SW-Dirty AlleyJun 25, 2026 · 79 m · 800 N CHARLES ST
- violation: HCD-Sanitation PropertyJun 22, 2026 · 100 m
- violation: HCD-Maintenance StructureJun 22, 2026 · 128 m · 26 E MOUNT VERNON PL
- violation: HCD-Maintenance StructureJun 22, 2026 · 131 m · 28 E MOUNT VERNON PL
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-11; sdat-properties: 2026-07-12;