Baltimore City · 21223

52 S FULTON AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$5,000
Land use
Residential (R)
Year built
1920
Last sale
Jun 2, 2022

This owner holds 5 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerUNITY PROPERTIES INC.
Land useResidential (R)
Total assessment$5,000 (cycle 2026)
Last saleJun 2, 2022
Year built1920
ZoningR-8
Vacant

Permits

8
TypeDescriptionCostIssued
BUSEUSE AS A SINGLE FAMILY HOMEDec 17, 2025
BRCMRough in for 10 plumbing fixtures reconstruct waste and water, no gas, water heater.$2,000Jul 28, 2025
BRCM********* CONTINUATION OF SCOPE OF WORK FROM PERMIT COM2024-79783 ********* SCOPE OF WORK: ------- INTERIOR ALTERATIONS ------- REPLACE BASEMENT SLAB IN KIND W/ VAPOR BARRIER AS PER CODE, 4'' CONCRETE, 4'' STONE, INSTALL DRAIN TILE AND AS PER CODE. ***** SEPARATE PERMIT NEEDED FOR PLUMBING WORK SUMP PUMP *********$300,000May 1, 2025
BRCMINSTALL DUCT WORK, AND 2.5 HEAT PUMP WITH AIR HANDLER SYSTEM, 3 BATH FANS, AND 1 DRYER VENT PER CODE ELECTRIC BY OTHERApr 29, 2025
COM2024INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (30) # BRANCH CIRCUITS/FEEDERS , (25) # LOW VOLTAGE AS PER CODE.$1,000Jan 28, 2025
COM2024RENOVATION OF EXISTING ROWHOME FOR SINGLE FAMILY ROWHOME. COMPLETE RENOVATION OF AN EXISTING ROW-HOUSE, ALL NEW INTERIOR FINISHES AND NEW INTERIOR FRAMING, ALL WINDOWS AND EXTERIOR DOORS WILL BE REMOVED AND REPLACED, USE 2X4 WOOD TO REFRAME A 3-BEDROOM 3 BATHROOM AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR MECHANICAL, PLUMBING AND ELECTRICAL WORK.***PER CHAP ATP: AT THE 1ST FLOOR, INSTALL ONE NEW 4-PANEL FIBERGLASS DOOR APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING TRANSOM TO BE RETAINED AND REPAIRED IN-KIND. ADDITIONAL SPECIFICATIONS FOR FRONT DOOR, TRANSOM, AND TRANSOM PANE TO BE SUBMITTED TO CHAP LATER IN AN AMENDMENT. AT THE BASEMENT, INSTALL TWO NEW SINGLE-PANE AWNING WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. AT THE 1ST, 2ND AND 3RD FLOORS, INSTALL EIGHT NEW 1/1 DOUBLE HUNG WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING BALTIMORE BULLNOSE TRIM TO BE RETAINED AND REPAIRED, IF NOT DETERIORATED BEYOND REPAIR. NEW DOORS AND WINDOWS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. NEW DOOR TRIM, WINDOWS AND WINDOW TRIM TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW7008 – ALABASTER. NEW DOOR TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW6244 – NAVAL. COMPLETE THE FOLLOWING WORK ON THE SIDE: AT THE 1ST AND 2ND FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. COMPLETE THE FOLLOWING WORK ON THE REAR: AT THE 1ST FLOOR, INSTALL ONE NEW 6-PANEL METAL DOOR. AT THE 1ST, 2ND, AND 3RD FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. NEW DOOR AND WINDOWS TO BE NON-HIGH GLOSS WHITE. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES.***$300,000Nov 14, 2024
COM2023SCOPE OF WORK: ------ CAT III DEMOLITION ----- DEMOLISH ALL INTERIOR FRAMING, WALLS, DOORS, FLOORS, WINDOWS IF EXISTING. REPLACE JOISTS AND FLOOR SYSTEMS AS PER PLAN. REPAIR INTERIOR MASONRY JOIST POCKETS, WINDOW HEADERS AND MASONRY AS REQUIRED (FOR SHORING OF EXISTING STRUCTURE). AS PER PLANS AND AS PER CODE. ******INTERIOR WALLS, STAIRS, MECHANICALS ON SEPARATE PERMIT. BUILDING IS TO BE UNOCCUPIED/ VACANT UNTIL A FUTURE DATE. INTERIOR WORK WILL BE DONE UNDER A SEPARATE PERMIT. THE BUILDING WILL NOT BE OCCUPIED AND WE ARE NOT SEEKING A CERTIFICATE OF OCCUPANCY UPON COMPLETION OF THE SCOPE OF WORK CONTAINED IN THIS SUBMISSION. ***************AS PER CHAP AUTHORIZATION TO PROCEED. • ALONG THE BUILDING’S RIDGELINE, REPLACE THE EXISTING FLAT ROOF SYSTEM IN ITS ENTIRETY WITH ONE (1) NEW MODIFIED BITUMEN ROOFING MEMBRANE SYSTEM. NEW ROOF TO BE SAME SIZE, COLOR, LOCATION, AND PITCH AS EXISTING HISTORIC ROOFING MEMBRANE. • ON THE FRONT FACADE, PROVIDE AT THE 2 ND AND 3 RD FLOORS THE NEW MASONRY BRICK AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW BRICKS TO BE SAME SIZE, COLOR, TEXTURE, PSI, BOND PATTERN, AND LOCATION MATERIAL AS EXISTING HISTORIC BRICK MASONRY. • ON THE REAR ELEVATION, PROVIDE AT THE 3 RD FLOOR NEW PRESSURE-TREATED WOOD FRAMING AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW WOOD TO BE SAME SIZE, LOCATION, AND MATERIAL AS EXISTING HISTORIC WOOD FRAMING. • ON THE SIDE ELEVATION, PROVIDE AT THE 1 ST AND 2ND FLOORS NEW PRESSURE-TREATED WOOD FRAMING AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW WOOD TO BE SAME SIZE, LOCATION, AND MATERIAL AS EXISTING HISTORIC WOOD FRAMING. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES.$12,500Dec 1, 2023
COM2023SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: CATEGORY I NON-STRUCTURAL DEMOLITION AND CLEAN OUT OF EXISTING STRUCTURE. CLEAN OUT OF ANY DEBRIS FROM ROOFING, FLOORING, INTERIOR DOORS, DEBRIS AND OTHER AREAS OF THE HOME. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, SEPARATE PERMIT WILL BE PULLED FOR ANY INTERIOR RENOVATIONS/TENANT FITOUT$2,500Oct 6, 2023

Violations

1
KindCategoryStatusFineBalanceDate
citationBC 123.8.1V$1,000$0May 16, 2024

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.