Assessment
| Owner | UNITY PROPERTIES, INC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $78,300 (cycle 2026) |
| Last sale | Jun 27, 2018 — $25,000 |
| Year built | 1870 |
| Zoning | R-8 |
| Vacant | — |
Permits
7| Type | Description | Cost | Issued |
|---|---|---|---|
| BUSE | USE AS A SINGLE FAMILY HOME | — | Dec 18, 2025 |
| BRCM | Rough in for 10 plumbing fixtures reconstruct the waste and water no gas | $1,000 | Apr 24, 2025 |
| BRCM | REPLACE BASEMENT SLAB IN IND W/ VAPOR BARRIER AS PER CODE, 4'' CONCRETE, 4'' STONE, INSTALL DRAIN TILE AND SUMP PUMP AS PER CODE. APPROXIMATELY X NUMBER OF SQ FT (ORIGINAL PERMIT COM2024-79779: APPROVED AS PER CHAP AUTHORIZATION TO PROCEED. COMPLETE THE FOLLOWING WORK ON THE FAÇADE: AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW WOOD CORNICE IN-KIND TO MATCH THE ARCHITECTURAL DETAILING AT 49 S. FULTON AVENUE. AT THE 1ST FLOOR, INSTALL ONE NEW 4-PANEL FIBERGLASS DOOR APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING TRANSOM TO BE RETAINED AND REPAIRED IN-KIND. ADDITIONAL SPECIFICATIONS FOR FRONT DOOR, TRANSOM, AND TRANSOM PANE TO BE SUBMITTED TO CHAP LATER IN AN AMENDMENT. AT THE BASEMENT, INSTALL TWO NEW SINGLE-PANE AWNING WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. AT THE 1ST, 2ND AND 3RD FLOORS, INSTALL EIGHT NEW 1/1 DOUBLE HUNG WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING BALTIMORE BULLNOSE TRIM TO BE RETAINED AND REPAIRED, IF NOT DETERIORATED BEYOND REPAIR. NEW DOORS AND WINDOWS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. INSTALL ONE NEW BLACK WROUGHT IRON HANDRAIL AT THE MAIN ENTRYWAY. INSTALL ONE NEW EXTERIOR LANTERN SCONCE ADJACENT TO THE MAIN ENTRYWAY. SCRAPE, PRIME, AND PAINT THE EXISTING MASONRY WALL IN ITS ENTIRETY WITH NEW SHERWIN WILLIAMS SW2839 – ROYCROFT COPPER RED. NEW CORNICE, DOOR TRIM, WINDOWS AND WINDOW TRIM TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW7008 – ALABASTER. NEW DOOR TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW6244 – NAVAL. COMPLETE THE FOLLOWING WORK ON THE SIDE: AT THE BASEMENT, INSTALL ONE NEW AWNING FIBERGLASS WINDOW. AT THE 1ST AND 2ND FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. REPOINT THE EXISTING MORTAR IN-KIND WITH NEW TYPE-N MORTAR, AT THE 1ST AND 2ND FLOORS. REPAIR THE EXISTING STUCCO COATING WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST AND 2ND FLOORS. NEW MORTAR TO BE SAME SIZE, COLOR, LOCATION, JOINT WIDTH, JOINT PATTERN, TEXTURE, AND PSI AS EXISTING HISTORIC MORTAR. REPLACE THE EXISTING WOOD SIDING WITH NEW HARDIE CEMENTITIOUS HORIZONTAL SMOOTH-LAP SIDING, AT THE 1ST FLOOR. EXISTING STUCCO WALL TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW7565 – OYSTER BAY. AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW K-STYLE WHITE ALUMINUM GUTTER AND K-STYLE WHITE ALUMINUM DOWNSPOUT. COMPLETE THE FOLLOWING WORK ON THE REAR: AT THE BASEMENT, INSTALL ONE NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOW WITHIN WINDOW WELL. AT THE 1ST FLOOR, INSTALL ONE NEW 6-PANEL METAL DOOR. AT THE 1ST, 2ND, AND 3RD FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. NEW DOOR AND WINDOWS TO BE NON-HIGH GLOSS WHITE. REPLACE THE EXISTING WOOD SIDING WITH NEW HARDIE CEMENTITIOUS HORIZONTAL SMOOTH-LAP SIDING, AT THE 3RD FLOOR. INSTALL ONE NEW PRESSURE-TREATED WOOD LANDING AND STAIRCASE AT THE 1ST FLOOR ABOVE THE EXISTING BASEMENT CMU WALL. REPOINT THE EXISTING MORTAR WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST, 2ND, AND 3RD FLOORS. REPAIR THE EXISTING STUCCO COATING WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST AND 2ND FLOORS. NEW MORTAR TO BE SAME SIZE, COLOR, LOCATION, JOINT WIDTH, JOINT PATTERN, TEXTURE, AND PSI AS EXISTING HISTORIC MORTAR. AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW K-STYLE WHITE ALUMINUM GUTTER AND K-STYLE WHITE ALUMINUM DOWNSPOUT. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES.RENOVATION OF EXISTING ROWHOME FOR SINGLE FAMILY ROWHOME. COMPLETE RENOVATION OF AN EXISTING ROW-HOUSE, ALL NEW INTERIOR FINISHES AND NEW INTERIOR FRAMING, ALL WINDOWS AND EXTERIOR DOORS WILL BE REMOVED AND REPLACED, USE 2X4 WOOD TO REFRAME A 3-BEDROOM 3 BATHROOM AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR MECHANICAL, PLUMBING AND ELECTRICAL WORK. | $300,000 | Apr 21, 2025 |
| COM2024 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (30) # BRANCH CIRCUITS/FEEDERS , (25) # LOW VOLTAGE AS PER CODE. | $1,000 | Jan 28, 2025 |
| COM2024 | APPROVED AS PER CHAP AUTHORIZATION TO PROCEED. COMPLETE THE FOLLOWING WORK ON THE FAÇADE: AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW WOOD CORNICE IN-KIND TO MATCH THE ARCHITECTURAL DETAILING AT 49 S. FULTON AVENUE. AT THE 1ST FLOOR, INSTALL ONE NEW 4-PANEL FIBERGLASS DOOR APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING TRANSOM TO BE RETAINED AND REPAIRED IN-KIND. ADDITIONAL SPECIFICATIONS FOR FRONT DOOR, TRANSOM, AND TRANSOM PANE TO BE SUBMITTED TO CHAP LATER IN AN AMENDMENT. AT THE BASEMENT, INSTALL TWO NEW SINGLE-PANE AWNING WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. AT THE 1ST, 2ND AND 3RD FLOORS, INSTALL EIGHT NEW 1/1 DOUBLE HUNG WOOD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. EXISTING BALTIMORE BULLNOSE TRIM TO BE RETAINED AND REPAIRED, IF NOT DETERIORATED BEYOND REPAIR. NEW DOORS AND WINDOWS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. INSTALL ONE NEW BLACK WROUGHT IRON HANDRAIL AT THE MAIN ENTRYWAY. INSTALL ONE NEW EXTERIOR LANTERN SCONCE ADJACENT TO THE MAIN ENTRYWAY. SCRAPE, PRIME, AND PAINT THE EXISTING MASONRY WALL IN ITS ENTIRETY WITH NEW SHERWIN WILLIAMS SW2839 – ROYCROFT COPPER RED. NEW CORNICE, DOOR TRIM, WINDOWS AND WINDOW TRIM TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW7008 – ALABASTER. NEW DOOR TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW6244 – NAVAL. COMPLETE THE FOLLOWING WORK ON THE SIDE: AT THE BASEMENT, INSTALL ONE NEW AWNING FIBERGLASS WINDOW. AT THE 1ST AND 2ND FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. REPOINT THE EXISTING MORTAR IN-KIND WITH NEW TYPE-N MORTAR, AT THE 1ST AND 2ND FLOORS. REPAIR THE EXISTING STUCCO COATING WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST AND 2ND FLOORS. NEW MORTAR TO BE SAME SIZE, COLOR, LOCATION, JOINT WIDTH, JOINT PATTERN, TEXTURE, AND PSI AS EXISTING HISTORIC MORTAR. REPLACE THE EXISTING WOOD SIDING WITH NEW HARDIE CEMENTITIOUS HORIZONTAL SMOOTH-LAP SIDING, AT THE 1ST FLOOR. EXISTING STUCCO WALL TO BE PAINTED WITH NEW SHERWIN WILLIAMS SW7565 – OYSTER BAY. AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW K-STYLE WHITE ALUMINUM GUTTER AND K-STYLE WHITE ALUMINUM DOWNSPOUT. COMPLETE THE FOLLOWING WORK ON THE REAR: AT THE BASEMENT, INSTALL ONE NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOW WITHIN WINDOW WELL. AT THE 1ST FLOOR, INSTALL ONE NEW 6-PANEL METAL DOOR. AT THE 1ST, 2ND, AND 3RD FLOORS, INSTALL NEW 1/1 DOUBLE HUNG FIBERGLASS WINDOWS. NEW WINDOWS AND DOORS TO FIT THE EXISTING MASONRY OPENINGS WITH NO FILLER OR ADDITIONAL FRAMING. NEW DOOR AND WINDOWS TO BE NON-HIGH GLOSS WHITE. REPLACE THE EXISTING WOOD SIDING WITH NEW HARDIE CEMENTITIOUS HORIZONTAL SMOOTH-LAP SIDING, AT THE 3RD FLOOR. INSTALL ONE NEW PRESSURE-TREATED WOOD LANDING AND STAIRCASE AT THE 1ST FLOOR ABOVE THE EXISTING BASEMENT CMU WALL. REPOINT THE EXISTING MORTAR WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST, 2ND, AND 3RD FLOORS. REPAIR THE EXISTING STUCCO COATING WITH NEW TYPE-N MORTAR IN-KIND, AT THE 1ST AND 2ND FLOORS. NEW MORTAR TO BE SAME SIZE, COLOR, LOCATION, JOINT WIDTH, JOINT PATTERN, TEXTURE, AND PSI AS EXISTING HISTORIC MORTAR. AT THE BUILDING’S ROOFLINE, INSTALL ONE NEW K-STYLE WHITE ALUMINUM GUTTER AND K-STYLE WHITE ALUMINUM DOWNSPOUT. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES.RENOVATION OF EXISTING ROWHOME FOR SINGLE FAMILY ROWHOME. COMPLETE RENOVATION OF AN EXISTING ROW-HOUSE, ALL NEW INTERIOR FINISHES AND NEW INTERIOR FRAMING, ALL WINDOWS AND EXTERIOR DOORS WILL BE REMOVED AND REPLACED, USE 2X4 WOOD TO REFRAME A 3-BEDROOM 3 BATHROOM AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR MECHANICAL, PLUMBING AND ELECTRICAL WORK. | $300,000 | Nov 14, 2024 |
| COM2023 | NOTICE TO PROCEED:ALONG THE BUILDING’S RIDGELINE, REPLACE THE EXISTING FLAT ROOF SYSTEM IN ITS ENTIRETY WITH ONE (1) NEW MODIFIED BITUMEN ROOFING MEMBRANE SYSTEM. NEW ROOF TO BE SAME SIZE, COLOR, LOCATION, AND PITCH AS EXISTING HISTORIC ROOFING MEMBRANE. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES DEMO ALL INTERIOR FRAMING, WALLS, DOORS, FLOORS, WINDOWS IF EXISTING. REPLACE JOISTS AND FLOOR SYSTEMS AS PER PLAN. REPAIR INTERIOR MASONRY JOIST POCKETS, WINDOW HEADERS AND MASONRY AS REQUIRED. INTERIOR WALLS, STAIRS, MECHANICALS ON SEPARATE PERMIT. BUILDING IS TO BE UNOCCUPIED/ VACANT UNTIL A FUTURE DATE. INTERIOR WORK WILL BE DONE UNDER A SEPARATE PERMIT. THE BUILDING WILL NOT BE OCCUPIED AND WE ARE NOT SEEKING A CERTIFICATE OF OCCUPANCY UPON COMPLETION OF THE SCOPE OF WORK CONTAINED IN THIS SUBMISSION. AS PER CODE AND AS PER PLANS, *PERMIT IS BEING APPROVED FOR USE AS SINGLE FAMILY DWELLING, ANY OTHER USE WILL MAKE THIS PERMIT INVALID AND SHOULD BE FILED USING THE EPLANS SYSTEM | $12,500 | Dec 5, 2023 |
| COM2023 | NON-STRUCTURAL DEMOLITION AND CLEAN OUT OF EXISTING STRUCTURE. CLEAN OUT OF ANY DEBRIS FROM ROOF, FLOORING, INTERIOR DOORS, DEBRIS AND OTHER AREAS OF THE HOME. AS PER CODE. | $2,500 | Oct 6, 2023 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: SW-HGWJul 6, 2026 · 86 m · 1710 LEMMON ST
- permit: BRCMJun 29, 2026 · 67 m · 1735 HOLLINS ST
- violation: HCD-Sanitation PropertyJun 27, 2026 · 49 m · 40 S FULTON AVE
- violation: HCD-Illegal DumpingJun 25, 2026 · 127 m · 1708 W PRATT ST
- permit: BRCMJun 25, 2026 · 127 m · 1826 W LOMBARD ST
- permit: BUSEJun 24, 2026 · 92 m · 1811 W LOMBARD ST
- violation: 13 4-5Jun 23, 2026 · 96 m · 1723 LEMMON ST
- violation: SW-HGWJun 22, 2026 · 123 m · 1712 W PRATT ST
- violation: SW-HGWJun 22, 2026 · 145 m · 1726 FREDERICK AVE
- violation: SW-Dirty AlleyJun 21, 2026 · 67 m · 1703 W LOMBARD ST